Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 12 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the charging and discharging relay open. 34 +If there is the "Overcurrent" error, the **charging **and **discharging **relay open. 35 35 ))) 36 36 37 37 == 3.6.2 Undervoltage protection == ... ... @@ -192,7 +192,7 @@ 192 192 193 193 (% class="box warningmessage" %) 194 194 ((( 195 - **If there is the "Battery cover error", the “Critical error” is generated and all relays open.**195 +If there is the "Battery cover error", **the “Critical error” is generated and all relays open.** 196 196 ))) 197 197 198 198 == 3.6.7 High humidity protection == ... ... @@ -254,7 +254,7 @@ 254 254 255 255 (% class="box warningmessage" %) 256 256 ((( 257 - **If there is the “Water” error, the “Critical error” is generated and all relays open.**257 +If there is the “Water” error,** the “Critical error” is generated and all relays open.** 258 258 ))) 259 259 260 260 == 3.6.9 Current sensor error == ... ... @@ -288,7 +288,7 @@ 288 288 289 289 (% class="box warningmessage" %) 290 290 ((( 291 - **If there is the “Current sensor error”, the “Critical error” is generated and all relays open.**291 +If there is the “Current sensor error”, **the “Critical error” is generated and all relays open.** 292 292 ))) 293 293 294 294 == 3.6.10 Short circuit protection == ... ... @@ -501,7 +501,7 @@ 501 501 502 502 To change the protection parameters of the temperature sensors circuits, select the menu "Protections → Temperature sensor error": 503 503 504 -[[ Caption>>image:1732214501360-654.png||data-xwiki-image-style-alignment="center" height="154" width="334"]]504 +[[Temperature sensor error settings>>image:1732214501360-654.png||data-xwiki-image-style-alignment="center" height="154" width="334"]] 505 505 506 506 In this section: 507 507 ... ... @@ -514,7 +514,7 @@ 514 514 515 515 (% class="box warningmessage" %) 516 516 ((( 517 - **If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the “Critical error” is generated and all relays open.**517 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.** 518 518 ))) 519 519 520 520 == 3.6.18 Logic high temperature protection == ... ... @@ -521,6 +521,7 @@ 521 521 522 522 To change the overheating protection parameters of BMS Logic boards, select the menu "Protections → Logic high temperature protection": 523 523 524 +[[Logic high temperature protection settings>>image:1732214545352-111.png||data-xwiki-image-style-alignment="center" height="156" width="309"]] 524 524 525 525 In this section: 526 526 ... ... @@ -541,7 +541,7 @@ 541 541 542 542 (% class="box infomessage" %) 543 543 ((( 544 - **Cell balancing is prohibited for overheated boards.**545 +Cell balancing is prohibited for overheated boards. 545 545 ))) 546 546 547 547 == 3.6.19 Logic offline protection == ... ... @@ -548,6 +548,7 @@ 548 548 549 549 To change the protection parameters from loss of communication with BMS Logic boards, select the menu "Protections → Logic offline protection": 550 550 552 +[[Logic offline protection settings>>image:1732214579147-515.png||data-xwiki-image-style-alignment="center" height="107" width="204"]] 551 551 552 552 In this section: 553 553 ... ... @@ -566,7 +566,7 @@ 566 566 567 567 (% class="box warningmessage" %) 568 568 ((( 569 - **If there is the "Logic offline" error, the “Critical error” is generated and all relays open.**571 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.** 570 570 ))) 571 571 572 572 == 3.6.20 Cell count protection == ... ... @@ -573,6 +573,7 @@ 573 573 574 574 To change the protection parameters from the mismatch of the number of cells to the set value, select the menu "Protections → Cell count protection": 575 575 578 +[[Cell count protection settings>>image:1732214641606-453.png||data-xwiki-image-style-alignment="center" height="178" width="341"]] 576 576 577 577 In this section: 578 578 ... ... @@ -594,7 +594,7 @@ 594 594 595 595 (% class="box warningmessage" %) 596 596 ((( 597 - **If there is the "Cell count error", the “Critical error” is generated and all relays open.**600 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 598 598 ))) 599 599 600 600 == 3.6.21 Logic count protection == ... ... @@ -601,6 +601,7 @@ 601 601 602 602 To change the protection parameters from the mismatch of the number of BMS Logic boards to the set value, select the menu "Protections → Logic count protection": 603 603 607 +[[Logic count protection settings>>image:1732214675358-202.png||data-xwiki-image-style-alignment="center" height="163" width="230"]] 604 604 605 605 In this section: 606 606 ... ... @@ -621,7 +621,7 @@ 621 621 622 622 (% class="box warningmessage" %) 623 623 ((( 624 - **If there is the "Logic count error", the “Critical error” is generated and all relays open.**628 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.** 625 625 ))) 626 626 627 627 == 3.6.22 WDT protection == ... ... @@ -630,6 +630,7 @@ 630 630 631 631 To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 632 632 637 +[[WDT protection settings>>image:1732214703914-144.png||data-xwiki-image-style-alignment="center" height="127" width="323"]] 633 633 634 634 In this section: 635 635 ... ... @@ -643,7 +643,7 @@ 643 643 644 644 (% class="box warningmessage" %) 645 645 ((( 646 - **If there is the "WDT reset" error, the “Critical error” is generated and all relays open.**651 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.** 647 647 ))) 648 648 649 649 == 3.6.23 Insulation monitoring == ... ... @@ -652,6 +652,7 @@ 652 652 653 653 To change the insulation monitoring parameters, select the menu "Protections → Insulation monitoring": 654 654 660 +[[Insulation monitoring settings>>image:1732214731490-961.png||data-xwiki-image-style-alignment="center" height="162" width="315"]] 655 655 656 656 In this section: 657 657 ... ... @@ -666,6 +666,7 @@ 666 666 667 667 To change the critical error parameters, select the menu "Protections → Critical error parameters": 668 668 675 +[[Critical error parameters settings>>image:1732214761141-983.png||data-xwiki-image-style-alignment="center" height="158" width="348"]] 669 669 670 670 In this section: 671 671 ... ... @@ -699,10 +699,29 @@ 699 699 700 700 == 3.6.25 General error parameters == 701 701 709 +To change the general error parameters, select the menu "Protections → General error parameters": 710 + 711 +[[General error parameters settings>>image:1732214987517-111.png||data-xwiki-image-style-alignment="center" height="535" width="349"]] 712 + 713 +In this section: 714 + 715 +* Enable – a flag to enable the protection; 716 +* Delay before setting the error, second; 717 +* Delay before clearing the error, second; 718 +* Lock the error until the device is reset; 719 +* Errors – a section to select errors that should trigger General error. 720 + 721 +The critical error flag is generated if at least one of the selected errors is generated during the “Delay before setting the error” time. 722 + 723 +The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 724 + 725 +The "General error" is //indicative //and can be linked to any discrete output of the board. 726 + 702 702 == 3.6.26 Low SOC signal == 703 703 704 704 To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 705 705 731 +[[Low SOC signal settings>>image:1732215174961-645.png||data-xwiki-image-style-alignment="center" height="186" width="325"]] 706 706 707 707 In this section: 708 708 ... ... @@ -727,6 +727,7 @@ 727 727 728 728 To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 729 729 756 +[[High charging current signal settings>>image:1732215211714-445.png||data-xwiki-image-style-alignment="center" height="181" width="322"]] 730 730 731 731 In this section: 732 732 ... ... @@ -751,6 +751,7 @@ 751 751 752 752 To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 753 753 781 +[[Heater control settings>>image:1732215252650-791.png||data-xwiki-image-style-alignment="center" height="233" width="370"]] 754 754 755 755 In this section: 756 756 ... ... @@ -781,6 +781,7 @@ 781 781 782 782 To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 783 783 812 +[[Heater (AUX) control settings>>image:1732215282135-420.png||data-xwiki-image-style-alignment="center" height="228" width="361"]] 784 784 785 785 In this section: 786 786 ... ... @@ -811,6 +811,7 @@ 811 811 812 812 To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 813 813 843 +[[Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="219" width="348"]] 814 814 815 815 In this section: 816 816 ... ... @@ -843,6 +843,7 @@ 843 843 844 844 To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 845 845 876 +[[Fault simulation settings>>image:1732215359330-850.png||data-xwiki-image-style-alignment="center" height="732" width="204"]] 846 846 847 847 In this section: 848 848
- 1732214641606-453.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.8 KB - Content
- 1732214675358-202.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- 1732214703914-144.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.6 KB - Content
- 1732214731490-961.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- 1732214761141-983.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- 1732214987517-111.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.3 KB - Content
- 1732215174961-645.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732215211714-445.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.4 KB - Content
- 1732215252650-791.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.9 KB - Content
- 1732215282135-420.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.3 KB - Content
- 1732215313977-499.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.8 KB - Content
- 1732215359330-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.8 KB - Content