Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,4 +4,129 @@ 4 4 5 5 To change the current protection of the battery, select the menu "Protections → Overcurrent protection": 6 6 7 -[[image:1732211959984-118.png]] 7 +[[Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]] 8 + 9 + 10 +In this section: 11 + 12 +* Enable – a flag to enable the protection; 13 +* Maximum charging current, А; 14 +* Tolerant charging current, А; 15 +* Maximum discharging current, А; 16 +* Tolerant discharging current, А; 17 +* Delay before setting the error, second; 18 +* Delay before clearing the error, second; 19 +* Lock the error until the device is reset – a flag to block the error until the board is restarted. 20 + 21 +As a result of operation of the current protection, the "Overcurrent" error is generated. 22 + 23 +Error generation conditions: 24 + 25 +* the current is positive (charging), and its modulo value is greater than the “Maximum charging current” value for the “Delay before setting the error” time; 26 +* the current is negative (discharging), and its modulo value is greater than the “Maximum discharging current” value for the “Delay before setting the error” time. 27 + 28 +Conditions for removing the error: 29 + 30 +* the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time; 31 +* the current is negative (discharging), and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time. 32 + 33 +(% class="box infomessage" %) 34 +((( 35 +If there is the "Overcurrent" error, the charging relay and discharging relay open. 36 +))) 37 + 38 +== 3.6.2 Undervoltage protection == 39 + 40 +The board implements battery protection from too low or too high voltage on the cells. 41 + 42 +To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection": 43 + 44 +[[Undervoltage protection settings>>image:1732212212350-294.png||data-xwiki-image-style-alignment="center" height="207" width="359"]] 45 + 46 + In this section: 47 + 48 +* Enable – a flag to enable the protection; 49 +* Minimum cell voltage, V; 50 +* Tolerant cell voltage, V; 51 +* Delay before setting the error, second; 52 +* Delay before clearing the error, second; 53 +* Lock the error until the device is reset. 54 + 55 +As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated. 56 + 57 +Error generation conditions: 58 + 59 +* the minimum voltage among all cells of the battery is less than the “Minimum cell voltage” value for the “Delay before setting the error” time. 60 + 61 +Conditions for removing the error: 62 + 63 +* the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 64 + 65 +(% class="box infomessage" %) 66 +((( 67 +If there is the "Undervoltage" error, the discharging relay opens. 68 +))) 69 + 70 +3.6.3 Overvoltage protection 71 + 72 +To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 73 + 74 +[[image:1732212357972-295.png]] 75 + 76 +In this section: 77 + 78 +* Enable – a flag to enable the protection; 79 +* Maximum cell voltage, V; 80 +* Tolerant cell voltage, V; 81 +* Delay before setting the error, second; 82 +* Delay before clearing the error, second; 83 +* Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated; 84 +* Lock the error until the device is reset. 85 + 86 +As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 87 + 88 +Error generation conditions: 89 + 90 +* the maximum voltage among all cells of the battery is greater than the “Maximum cell voltage” value for the “Delay before setting the error” time. 91 + 92 +Conditions for removing the error: 93 + 94 +* the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 95 + 96 +(% class="box infomessage" %) 97 +((( 98 +If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 99 +))) 100 + 101 +3.6.4 Low temperature protection 102 + 103 +3.6.5 High temperature protection 104 + 105 +3.6.6 Battery cover protection 106 + 107 +3.6.7 High humidity protection 108 + 109 +3.6.8 Water protection 110 +3.6.9 Current sensor error 111 +3.6.10 Short circuit protection 112 +3.6.11 Contactor high temperature protection 113 +3.6.12 Unallowable charging protection 114 +3.6.13 Stuck contactor protection 115 +3.6.14 Contactor feedback check 116 +3.6.15 Charging contactor cycles protection 117 +3.6.16 Discharging contactor cycles protection 118 +3.6.17 Temperature sensor error 119 +3.6.18 Logic high temperature protection 120 +3.6.19 Logic offline protection 121 +3.6.20 Cell count protection 122 +3.6.21 Logic count protection 123 +3.6. WDT protection 124 +Insulation monitoring 125 +Critical error parameters 126 +General error parameters 127 +Low SOC signal 128 +High charging current signal 129 +Heater control 130 +Heater (AUX) control 131 +Cooler control 132 +Fault simulation
- 1732212212350-294.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.0 KB - Content
- 1732212357972-295.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.5 KB - Content