Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 16 added, 0 removed)
- 1732214468462-541.png
- 1732214501360-654.png
- 1732214545352-111.png
- 1732214579147-515.png
- 1732214641606-453.png
- 1732214675358-202.png
- 1732214703914-144.png
- 1732214731490-961.png
- 1732214761141-983.png
- 1732214987517-111.png
- 1732215174961-645.png
- 1732215211714-445.png
- 1732215252650-791.png
- 1732215282135-420.png
- 1732215313977-499.png
- 1732215359330-850.png
Details
- Page properties
-
- Content
-
... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the charging and discharging relay open. 34 +If there is the "Overcurrent" error, the **charging **and **discharging **relay open. 35 35 ))) 36 36 37 37 == 3.6.2 Undervoltage protection == ... ... @@ -63,7 +63,7 @@ 63 63 64 64 (% class="box infomessage" %) 65 65 ((( 66 -If there is the "Undervoltage" error, the discharging relay opens. 66 +If there is the "Undervoltage" error, the **discharging **relay opens. 67 67 ))) 68 68 69 69 3.6.3 Overvoltage protection ... ... @@ -94,7 +94,7 @@ 94 94 95 95 (% class="box infomessage" %) 96 96 ((( 97 -If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 97 +If there is the "Overvoltage" error, the **charging **relay and **discharging **relay opens (if the “Switch off the discharging relay on error” flag is set). 98 98 ))) 99 99 100 100 == 3.6.4 Low temperature protection == ... ... @@ -128,8 +128,8 @@ 128 128 129 129 (% class="box infomessage" %) 130 130 ((( 131 -If there is the "Low CH temperature" error, the charging relay opens. 132 -If there is the "Low DCH temperature" error, the discharging relay opens. 131 +If there is the "Low CH temperature" error, the **charging **relay opens. 132 +If there is the "Low DCH temperature" error, the **discharging **relay opens. 133 133 ))) 134 134 135 135 == 3.6.5 High temperature protection == ... ... @@ -163,8 +163,8 @@ 163 163 164 164 (% class="box infomessage" %) 165 165 ((( 166 -If there is the "High CH temperature" error, the charging relay opens. 167 -If there is the "High DCH temperature" error, the discharging relay opens. 166 +If there is the "High CH temperature" error, the **charging **relay opens. 167 +If there is the "High DCH temperature" error, the **discharging **relay opens. 168 168 ))) 169 169 170 170 == 3.6.6 Battery cover protection == ... ... @@ -192,7 +192,7 @@ 192 192 193 193 (% class="box warningmessage" %) 194 194 ((( 195 - **If there is the "Battery cover error", the “Critical error” is generated and all relays open.**195 +If there is the "Battery cover error", the **“Critical error” **is generated and **all relays open.** 196 196 ))) 197 197 198 198 == 3.6.7 High humidity protection == ... ... @@ -254,7 +254,7 @@ 254 254 255 255 (% class="box warningmessage" %) 256 256 ((( 257 - **If there is the “Water” error, the “Critical error” is generated and all relays open.**257 +If there is the “Water” error,** **the **“Critical error”** is generated and **all relays open.** 258 258 ))) 259 259 260 260 == 3.6.9 Current sensor error == ... ... @@ -288,7 +288,7 @@ 288 288 289 289 (% class="box warningmessage" %) 290 290 ((( 291 - **If there is the “Current sensor error”, the “Critical error” is generated and all relays open.**291 +If there is the “Current sensor error”, the **“Critical error” **is generated and **all relays open.** 292 292 ))) 293 293 294 294 == 3.6.10 Short circuit protection == ... ... @@ -322,7 +322,7 @@ 322 322 323 323 (% class="box infomessage" %) 324 324 ((( 325 -If there is the "Short circuit" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 325 +If there is the "Short circuit" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 326 326 ))) 327 327 328 328 == 3.6.11 Contactor high temperature protection == ... ... @@ -395,6 +395,7 @@ 395 395 396 396 To change the protection parameters against sticking, select the menu "Protections → Stuck contactor protection": 397 397 398 +[[Stuck contactor protection settings>>image:1732214367207-318.png||data-xwiki-image-style-alignment="center" height="152" width="331"]] 398 398 399 399 In this section: 400 400 ... ... @@ -415,6 +415,7 @@ 415 415 416 416 To change the contactor feedback check parameters, select the menu "Protections → Contactor feedback check": 417 417 419 +[[Contactor feedback check settings>>image:1732214400721-274.png||data-xwiki-image-style-alignment="center" height="150" width="323"]] 418 418 419 419 In this section: 420 420 ... ... @@ -433,6 +433,7 @@ 433 433 434 434 To change the protection parameters against high frequency switching of the charging contactor, select the menu "Protections → Charging contactor cycles protection": 435 435 438 +[[Charging contactor cycles protection settings>>image:1732214432750-543.png||data-xwiki-image-style-alignment="center" height="260" width="336"]] 436 436 437 437 In this section: 438 438 ... ... @@ -465,6 +465,7 @@ 465 465 466 466 To change the protection parameters against high frequency switching of the discharging contactor, select the menu "Protections → Discharging contactor cycles protection": 467 467 471 +[[Discharging contactor cycles protection settings>>image:1732214468462-541.png||data-xwiki-image-style-alignment="center" height="269" width="346"]] 468 468 469 469 In this section: 470 470 ... ... @@ -497,6 +497,7 @@ 497 497 498 498 To change the protection parameters of the temperature sensors circuits, select the menu "Protections → Temperature sensor error": 499 499 504 +[[Temperature sensor error settings>>image:1732214501360-654.png||data-xwiki-image-style-alignment="center" height="154" width="334"]] 500 500 501 501 In this section: 502 502 ... ... @@ -509,7 +509,7 @@ 509 509 510 510 (% class="box warningmessage" %) 511 511 ((( 512 - **If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the “Critical error” is generated and all relays open.**517 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, **the “Critical error” is generated and all relays open.** 513 513 ))) 514 514 515 515 == 3.6.18 Logic high temperature protection == ... ... @@ -516,6 +516,7 @@ 516 516 517 517 To change the overheating protection parameters of BMS Logic boards, select the menu "Protections → Logic high temperature protection": 518 518 524 +[[Logic high temperature protection settings>>image:1732214545352-111.png||data-xwiki-image-style-alignment="center" height="156" width="309"]] 519 519 520 520 In this section: 521 521 ... ... @@ -536,7 +536,7 @@ 536 536 537 537 (% class="box infomessage" %) 538 538 ((( 539 - **Cell balancing is prohibited for overheated boards.**545 +Cell balancing is prohibited for overheated boards. 540 540 ))) 541 541 542 542 == 3.6.19 Logic offline protection == ... ... @@ -543,6 +543,7 @@ 543 543 544 544 To change the protection parameters from loss of communication with BMS Logic boards, select the menu "Protections → Logic offline protection": 545 545 552 +[[Logic offline protection settings>>image:1732214579147-515.png||data-xwiki-image-style-alignment="center" height="107" width="204"]] 546 546 547 547 In this section: 548 548 ... ... @@ -561,7 +561,7 @@ 561 561 562 562 (% class="box warningmessage" %) 563 563 ((( 564 - **If there is the "Logic offline" error, the “Critical error” is generated and all relays open.**571 +If there is the "Logic offline" error, **the “Critical error” is generated and all relays open.** 565 565 ))) 566 566 567 567 == 3.6.20 Cell count protection == ... ... @@ -568,6 +568,7 @@ 568 568 569 569 To change the protection parameters from the mismatch of the number of cells to the set value, select the menu "Protections → Cell count protection": 570 570 578 +[[Cell count protection settings>>image:1732214641606-453.png||data-xwiki-image-style-alignment="center" height="178" width="341"]] 571 571 572 572 In this section: 573 573 ... ... @@ -589,7 +589,7 @@ 589 589 590 590 (% class="box warningmessage" %) 591 591 ((( 592 - **If there is the "Cell count error", the “Critical error” is generated and all relays open.**600 +If there is the "Cell count error",** the “Critical error” is generated and all relays open.** 593 593 ))) 594 594 595 595 == 3.6.21 Logic count protection == ... ... @@ -596,6 +596,7 @@ 596 596 597 597 To change the protection parameters from the mismatch of the number of BMS Logic boards to the set value, select the menu "Protections → Logic count protection": 598 598 607 +[[Logic count protection settings>>image:1732214675358-202.png||data-xwiki-image-style-alignment="center" height="163" width="230"]] 599 599 600 600 In this section: 601 601 ... ... @@ -616,7 +616,7 @@ 616 616 617 617 (% class="box warningmessage" %) 618 618 ((( 619 - **If there is the "Logic count error", the “Critical error” is generated and all relays open.**628 +If there is the "Logic count error", **the “Critical error” is generated and all relays open.** 620 620 ))) 621 621 622 622 == 3.6.22 WDT protection == ... ... @@ -625,6 +625,7 @@ 625 625 626 626 To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 627 627 637 +[[WDT protection settings>>image:1732214703914-144.png||data-xwiki-image-style-alignment="center" height="127" width="323"]] 628 628 629 629 In this section: 630 630 ... ... @@ -638,7 +638,7 @@ 638 638 639 639 (% class="box warningmessage" %) 640 640 ((( 641 - **If there is the "WDT reset" error, the “Critical error” is generated and all relays open.**651 +If there is the "WDT reset" error, **the “Critical error” is generated and all relays open.** 642 642 ))) 643 643 644 644 == 3.6.23 Insulation monitoring == ... ... @@ -647,6 +647,7 @@ 647 647 648 648 To change the insulation monitoring parameters, select the menu "Protections → Insulation monitoring": 649 649 660 +[[Insulation monitoring settings>>image:1732214731490-961.png||data-xwiki-image-style-alignment="center" height="162" width="315"]] 650 650 651 651 In this section: 652 652 ... ... @@ -661,6 +661,7 @@ 661 661 662 662 To change the critical error parameters, select the menu "Protections → Critical error parameters": 663 663 675 +[[Critical error parameters settings>>image:1732214761141-983.png||data-xwiki-image-style-alignment="center" height="158" width="348"]] 664 664 665 665 In this section: 666 666 ... ... @@ -694,10 +694,29 @@ 694 694 695 695 == 3.6.25 General error parameters == 696 696 709 +To change the general error parameters, select the menu "Protections → General error parameters": 710 + 711 +[[General error parameters settings>>image:1732214987517-111.png||data-xwiki-image-style-alignment="center" height="535" width="349"]] 712 + 713 +In this section: 714 + 715 +* Enable – a flag to enable the protection; 716 +* Delay before setting the error, second; 717 +* Delay before clearing the error, second; 718 +* Lock the error until the device is reset; 719 +* Errors – a section to select errors that should trigger General error. 720 + 721 +The critical error flag is generated if at least one of the selected errors is generated during the “Delay before setting the error” time. 722 + 723 +The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 724 + 725 +The "General error" is //indicative //and can be linked to any discrete output of the board. 726 + 697 697 == 3.6.26 Low SOC signal == 698 698 699 699 To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 700 700 731 +[[Low SOC signal settings>>image:1732215174961-645.png||data-xwiki-image-style-alignment="center" height="186" width="325"]] 701 701 702 702 In this section: 703 703 ... ... @@ -722,6 +722,7 @@ 722 722 723 723 To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 724 724 756 +[[High charging current signal settings>>image:1732215211714-445.png||data-xwiki-image-style-alignment="center" height="181" width="322"]] 725 725 726 726 In this section: 727 727 ... ... @@ -746,6 +746,7 @@ 746 746 747 747 To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 748 748 781 +[[Heater control settings>>image:1732215252650-791.png||data-xwiki-image-style-alignment="center" height="233" width="370"]] 749 749 750 750 In this section: 751 751 ... ... @@ -776,6 +776,7 @@ 776 776 777 777 To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 778 778 812 +[[Heater (AUX) control settings>>image:1732215282135-420.png||data-xwiki-image-style-alignment="center" height="228" width="361"]] 779 779 780 780 In this section: 781 781 ... ... @@ -806,6 +806,7 @@ 806 806 807 807 To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 808 808 843 +[[Cooler control settings>>image:1732215313977-499.png||data-xwiki-image-style-alignment="center" height="219" width="348"]] 809 809 810 810 In this section: 811 811 ... ... @@ -838,6 +838,7 @@ 838 838 839 839 To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 840 840 876 +[[Fault simulation settings>>image:1732215359330-850.png||data-xwiki-image-style-alignment="center" height="732" width="204"]] 841 841 842 842 In this section: 843 843
- 1732214468462-541.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.3 KB - Content
- 1732214501360-654.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- 1732214545352-111.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- 1732214579147-515.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.5 KB - Content
- 1732214641606-453.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.8 KB - Content
- 1732214675358-202.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- 1732214703914-144.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.6 KB - Content
- 1732214731490-961.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- 1732214761141-983.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- 1732214987517-111.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.3 KB - Content
- 1732215174961-645.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732215211714-445.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.4 KB - Content
- 1732215252650-791.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.9 KB - Content
- 1732215282135-420.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.3 KB - Content
- 1732215313977-499.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.8 KB - Content
- 1732215359330-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.8 KB - Content