Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 23 added, 0 removed)
- 1732214183037-761.png
- 1732214207026-822.png
- 1732214237851-405.png
- 1732214272022-547.png
- 1732214367207-318.png
- 1732214400721-274.png
- 1732214432750-543.png
- 1732214468462-541.png
- 1732214501360-654.png
- 1732214545352-111.png
- 1732214579147-515.png
- 1732214641606-453.png
- 1732214675358-202.png
- 1732214703914-144.png
- 1732214731490-961.png
- 1732214761141-983.png
- 1732214987517-111.png
- 1732215174961-645.png
- 1732215211714-445.png
- 1732215252650-791.png
- 1732215282135-420.png
- 1732215313977-499.png
- 1732215359330-850.png
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -drafts. bms-main-2-1.configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -4,7 +4,7 @@ 4 4 5 5 To change the current protection of the battery, select the menu "Protections → Overcurrent protection": 6 6 7 -[[ Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]]7 +[[image:1732211959984-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="266" width="386"]] 8 8 9 9 In this section: 10 10 ... ... @@ -31,16 +31,16 @@ 31 31 32 32 (% class="box infomessage" %) 33 33 ((( 34 -If there is the "Overcurrent" error, the charging and discharging relay open. 34 +If there is the "Overcurrent" error, the **charging **and **discharging **relay open. 35 35 ))) 36 36 37 -== 37 +== 3.6.2 Undervoltage protection == 38 38 39 39 The board implements battery protection from too low or too high voltage on the cells. 40 40 41 41 To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection": 42 42 43 -[[ Undervoltage protection settings>>image:1732212212350-294.png||data-xwiki-image-style-alignment="center" height="207" width="359"]]43 +[[image:1732212212350-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="359"]] 44 44 45 45 In this section: 46 46 ... ... @@ -63,14 +63,14 @@ 63 63 64 64 (% class="box infomessage" %) 65 65 ((( 66 -If there is the "Undervoltage" error, the discharging relay opens. 66 +If there is the "Undervoltage" error, the **discharging **relay opens. 67 67 ))) 68 68 69 -3.6.3 Overvoltage protection 69 +== 3.6.3 Overvoltage protection == 70 70 71 71 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 72 72 73 -[[ Overvoltage protection settings>>image:1732212357972-295.png||data-xwiki-image-style-alignment="center" height="218" width="338"]]73 +[[image:1732212357972-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="338"]] 74 74 75 75 In this section: 76 76 ... ... @@ -94,7 +94,7 @@ 94 94 95 95 (% class="box infomessage" %) 96 96 ((( 97 -If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 97 +If there is the "Overvoltage" error, the **charging **relay and **discharging **relay opens (if the “Switch off the discharging relay on error” flag is set). 98 98 ))) 99 99 100 100 == 3.6.4 Low temperature protection == ... ... @@ -103,7 +103,7 @@ 103 103 104 104 To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 105 105 106 -[[ Low temperature protection settings>>image:1732213953083-955.png||data-xwiki-image-style-alignment="center" height="237" width="338"]]106 +[[image:1732213953083-955.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="338"]] 107 107 108 108 In this section: 109 109 ... ... @@ -128,8 +128,8 @@ 128 128 129 129 (% class="box infomessage" %) 130 130 ((( 131 -If there is the "Low CH temperature" error, the charging relay opens. 132 -If there is the "Low DCH temperature" error, the discharging relay opens. 131 +If there is the "Low CH temperature" error, the **charging **relay opens. 132 +If there is the "Low DCH temperature" error, the **discharging **relay opens. 133 133 ))) 134 134 135 135 == 3.6.5 High temperature protection == ... ... @@ -138,7 +138,7 @@ 138 138 139 139 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 140 140 141 -[[ High temperature protection settings>>image:1732213990755-759.png||data-xwiki-image-style-alignment="center" height="258" width="370"]]141 +[[image:1732213990755-759.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="258" width="370"]] 142 142 143 143 In this section: 144 144 ... ... @@ -163,8 +163,8 @@ 163 163 164 164 (% class="box infomessage" %) 165 165 ((( 166 -If there is the "High CH temperature" error, the charging relay opens. 167 -If there is the "High DCH temperature" error, the discharging relay opens. 166 +If there is the "High CH temperature" error, the **charging **relay opens. 167 +If there is the "High DCH temperature" error, the **discharging **relay opens. 168 168 ))) 169 169 170 170 == 3.6.6 Battery cover protection == ... ... @@ -171,7 +171,7 @@ 171 171 172 172 To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 173 173 174 -[[ Battery cover protection settings>>image:1732214030014-281.png||data-xwiki-image-style-alignment="center" height="155" width="334"]]174 +[[image:1732214030014-281.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="155" width="334"]] 175 175 176 176 In this section: 177 177 ... ... @@ -192,7 +192,7 @@ 192 192 193 193 (% class="box warningmessage" %) 194 194 ((( 195 - **If there is the "Battery cover error", the “Critical error” is generated and all relays open.**195 +If there is the "Battery cover error", the **“Critical error” **is generated and **all relays open.** 196 196 ))) 197 197 198 198 == 3.6.7 High humidity protection == ... ... @@ -201,7 +201,7 @@ 201 201 202 202 To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 203 203 204 -[[ High humidity protection settings>>image:1732214076060-358.png||data-xwiki-image-style-alignment="center" height="185" width="321"]]204 +[[image:1732214076060-358.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="185" width="321"]] 205 205 206 206 In this section: 207 207 ... ... @@ -231,7 +231,7 @@ 231 231 232 232 To change the protection parameters of the battery from water, select the menu "Protections → Water protection": 233 233 234 -[[ Water protection settings>>image:1732214111990-184.png||data-xwiki-image-style-alignment="center" height="199" width="340"]]234 +[[image:1732214111990-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="199" width="340"]] 235 235 236 236 In this section: 237 237 ... ... @@ -254,7 +254,7 @@ 254 254 255 255 (% class="box warningmessage" %) 256 256 ((( 257 - **If there is the “Water” error, the “Critical error” is generated and all relays open.**257 +If there is the “Water” error,** **the **“Critical error”** is generated and **all relays open.** 258 258 ))) 259 259 260 260 == 3.6.9 Current sensor error == ... ... @@ -263,7 +263,7 @@ 263 263 264 264 To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error": 265 265 266 -[[image:1732214146724-132.png]] 266 +[[image:1732214146724-132.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="438" width="365"]] 267 267 268 268 In this section: 269 269 ... ... @@ -288,7 +288,7 @@ 288 288 289 289 (% class="box warningmessage" %) 290 290 ((( 291 - **If there is the “Current sensor error”, the “Critical error” is generated and all relays open.**291 +If there is the “Current sensor error”, the **“Critical error” **is generated and **all relays open.** 292 292 ))) 293 293 294 294 == 3.6.10 Short circuit protection == ... ... @@ -297,6 +297,7 @@ 297 297 298 298 To change the protection parameters from short circuit, select the menu "Protections → Short circuit protection": 299 299 300 +[[image:1732214207026-822.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="528" width="371"]] 300 300 301 301 In this section: 302 302 ... ... @@ -321,7 +321,7 @@ 321 321 322 322 (% class="box infomessage" %) 323 323 ((( 324 -If there is the "Short circuit" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 325 +If there is the "Short circuit" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 325 325 ))) 326 326 327 327 == 3.6.11 Contactor high temperature protection == ... ... @@ -330,6 +330,7 @@ 330 330 331 331 To change the overheating protection parameters of power contactors, select the menu "Protections → Contactor high temperature protection": 332 332 334 +[[image:1732214237851-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="234" width="336"]] 333 333 334 334 In this section: 335 335 ... ... @@ -354,7 +354,7 @@ 354 354 355 355 (% class="box infomessage" %) 356 356 ((( 357 -If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set). 359 +If there is the "Contactor high temperature" error, the **charging **relay opens (the “Switch off the charging relay on error” flag is set) and the **discharging **relay opens (the “Switch off the discharging relay on error flag” is set). 358 358 ))) 359 359 360 360 == 3.6.12 Unallowable charging protection == ... ... @@ -363,6 +363,7 @@ 363 363 364 364 To change the parameters of the unallowable charging protection, select the menu "Protections → Unallowable charging protection": 365 365 368 +[[image:1732214272022-547.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="312"]] 366 366 367 367 In this section: 368 368 ... ... @@ -383,7 +383,7 @@ 383 383 384 384 (% class="box infomessage" %) 385 385 ((( 386 -If there is the "Unallowable charging" error, the discharging relay opens. 389 +If there is the "Unallowable charging" error, the **discharging **relay opens. 387 387 ))) 388 388 389 389 == 3.6.13 Stuck contactor protection == ... ... @@ -392,6 +392,7 @@ 392 392 393 393 To change the protection parameters against sticking, select the menu "Protections → Stuck contactor protection": 394 394 398 +[[image:1732214367207-318.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="152" width="331"]] 395 395 396 396 In this section: 397 397 ... ... @@ -406,12 +406,18 @@ 406 406 407 407 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 408 408 413 +(% class="box warningmessage" %) 414 +((( 415 +If there is the “Stuck contactor error”, the **“Critical error” **is generated and **all relays open.** 416 +))) 417 + 409 409 == 3.6.14 Contactor feedback check == 410 410 411 -The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see se ction420 +The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see [[3.3 Input and output signals>>path:/bin/view/drafts/BMS%20Main%202.1/3.%20Configuration/3.3%20Input%20and%20output%20signals/]]). 412 412 413 413 To change the contactor feedback check parameters, select the menu "Protections → Contactor feedback check": 414 414 424 +[[image:1732214400721-274.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="150" width="323"]] 415 415 416 416 In this section: 417 417 ... ... @@ -424,6 +424,11 @@ 424 424 425 425 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 426 426 437 +(% class="box warningmessage" %) 438 +((( 439 +If there is the contactor feedback error, the **“Critical error” **is generated and **all relays open.** 440 +))) 441 + 427 427 == 3.6.15 Charging contactor cycles protection == 428 428 429 429 The BMS protects the charging contactor against frequent switching. ... ... @@ -430,6 +430,7 @@ 430 430 431 431 To change the protection parameters against high frequency switching of the charging contactor, select the menu "Protections → Charging contactor cycles protection": 432 432 448 +[[image:1732214432750-543.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="260" width="336"]] 433 433 434 434 In this section: 435 435 ... ... @@ -453,7 +453,7 @@ 453 453 454 454 (% class="box infomessage" %) 455 455 ((( 456 -If there is the "CH contactor cycles error" error, the charging relay opens. 472 +If there is the "CH contactor cycles error" error, the **charging **relay opens. 457 457 ))) 458 458 459 459 == 3.6.16 Discharging contactor cycles protection == ... ... @@ -462,6 +462,7 @@ 462 462 463 463 To change the protection parameters against high frequency switching of the discharging contactor, select the menu "Protections → Discharging contactor cycles protection": 464 464 481 +[[image:1732214468462-541.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="269" width="346"]] 465 465 466 466 In this section: 467 467 ... ... @@ -485,7 +485,7 @@ 485 485 486 486 (% class="box infomessage" %) 487 487 ((( 488 -If there is the "DCH contactor cycles error" error, the discharging relay opens. 505 +If there is the "DCH contactor cycles error" error, the **discharging **relay opens. 489 489 ))) 490 490 491 491 == 3.6.17 Temperature sensor error == ... ... @@ -494,6 +494,7 @@ 494 494 495 495 To change the protection parameters of the temperature sensors circuits, select the menu "Protections → Temperature sensor error": 496 496 514 +[[image:1732214501360-654.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="154" width="334"]] 497 497 498 498 In this section: 499 499 ... ... @@ -506,7 +506,7 @@ 506 506 507 507 (% class="box warningmessage" %) 508 508 ((( 509 - **If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the “Critical error” is generated and all relays open.**527 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error” **is generated and **all relays open.** 510 510 ))) 511 511 512 512 == 3.6.18 Logic high temperature protection == ... ... @@ -513,6 +513,7 @@ 513 513 514 514 To change the overheating protection parameters of BMS Logic boards, select the menu "Protections → Logic high temperature protection": 515 515 534 +[[image:1732214545352-111.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="156" width="309"]] 516 516 517 517 In this section: 518 518 ... ... @@ -533,7 +533,7 @@ 533 533 534 534 (% class="box infomessage" %) 535 535 ((( 536 - **Cell balancing is prohibited for overheated boards.**555 +Cell balancing is prohibited for overheated boards. 537 537 ))) 538 538 539 539 == 3.6.19 Logic offline protection == ... ... @@ -540,6 +540,7 @@ 540 540 541 541 To change the protection parameters from loss of communication with BMS Logic boards, select the menu "Protections → Logic offline protection": 542 542 562 +[[image:1732214579147-515.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="204"]] 543 543 544 544 In this section: 545 545 ... ... @@ -558,7 +558,7 @@ 558 558 559 559 (% class="box warningmessage" %) 560 560 ((( 561 - **If there is the "Logic offline" error, the “Critical error” is generated and all relays open.**581 +If there is the "Logic offline" error, the **“Critical error”** is generated and **all relays open.** 562 562 ))) 563 563 564 564 == 3.6.20 Cell count protection == ... ... @@ -565,6 +565,7 @@ 565 565 566 566 To change the protection parameters from the mismatch of the number of cells to the set value, select the menu "Protections → Cell count protection": 567 567 588 +[[image:1732214641606-453.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="341"]] 568 568 569 569 In this section: 570 570 ... ... @@ -586,7 +586,7 @@ 586 586 587 587 (% class="box warningmessage" %) 588 588 ((( 589 - **If there is the "Cell count error", the “Critical error” is generated and all relays open.**610 +If there is the "Cell count error",** **the **“Critical error”** is generated and **all relays open.** 590 590 ))) 591 591 592 592 == 3.6.21 Logic count protection == ... ... @@ -593,6 +593,7 @@ 593 593 594 594 To change the protection parameters from the mismatch of the number of BMS Logic boards to the set value, select the menu "Protections → Logic count protection": 595 595 617 +[[image:1732214675358-202.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="230"]] 596 596 597 597 In this section: 598 598 ... ... @@ -613,7 +613,7 @@ 613 613 614 614 (% class="box warningmessage" %) 615 615 ((( 616 - **If there is the "Logic count error", the “Critical error” is generated and all relays open.**638 +If there is the "Logic count error", the **“Critical error” **is generated and **all relays open.** 617 617 ))) 618 618 619 619 == 3.6.22 WDT protection == ... ... @@ -622,6 +622,7 @@ 622 622 623 623 To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 624 624 647 +[[image:1732214703914-144.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="323"]] 625 625 626 626 In this section: 627 627 ... ... @@ -635,7 +635,7 @@ 635 635 636 636 (% class="box warningmessage" %) 637 637 ((( 638 - **If there is the "WDT reset" error, the “Critical error” is generated and661 +If there is the "WDT reset" error, the **“Critical error”** is generated and** all relays open.** 639 639 ))) 640 640 641 641 == 3.6.23 Insulation monitoring == ... ... @@ -644,6 +644,7 @@ 644 644 645 645 To change the insulation monitoring parameters, select the menu "Protections → Insulation monitoring": 646 646 670 +[[image:1732214731490-961.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="315"]] 647 647 648 648 In this section: 649 649 ... ... @@ -654,10 +654,16 @@ 654 654 655 655 Error is set if corresponding discrete input is set up and it received logical zero. 656 656 681 +(% class="box warningmessage" %) 682 +((( 683 +If there is the "Insulation monitoring" error, the **“Critical error”** is generated and** all relays open.** 684 +))) 685 + 657 657 == 3.6.24 Critical error parameters == 658 658 659 659 To change the critical error parameters, select the menu "Protections → Critical error parameters": 660 660 690 +[[image:1732214761141-983.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="348"]] 661 661 662 662 In this section: 663 663 ... ... @@ -677,10 +677,13 @@ 677 677 * “No temp. sensors”; 678 678 * “Temp. sensor is shorted”; 679 679 * “Current sensor error”; 710 +* "Stuck contactor"; 711 +* "Contactor feedback"; 680 680 * “Shunt offline”; 681 681 * “Shunt error”; 682 682 * “Settings error”; 683 -* “WDT reset”. 715 +* “WDT reset” 716 +* "Insulation monitoring". 684 684 685 685 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 686 686 ... ... @@ -691,10 +691,32 @@ 691 691 692 692 == 3.6.25 General error parameters == 693 693 727 +To change the general error parameters, select the menu "Protections → General error parameters": 728 + 729 +[[image:1732214987517-111.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="535" width="349"]] 730 + 731 +In this section: 732 + 733 +* Enable – a flag to enable the protection; 734 +* Delay before setting the error, second; 735 +* Delay before clearing the error, second; 736 +* Lock the error until the device is reset; 737 +* Errors – a section to select errors that should trigger General error. 738 + 739 +The critical error flag is generated if at least one of the selected errors is generated during the “Delay before setting the error” time. 740 + 741 +The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 742 + 743 +(% class="box infomessage" %) 744 +((( 745 +The "General error" is //indicative //and can be linked to any discrete output of the board. 746 +))) 747 + 694 694 == 3.6.26 Low SOC signal == 695 695 696 696 To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 697 697 752 +[[image:1732215174961-645.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="186" width="325"]] 698 698 699 699 In this section: 700 700 ... ... @@ -713,12 +713,16 @@ 713 713 714 714 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 715 715 771 +(% class="box infomessage" %) 772 +((( 716 716 The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 774 +))) 717 717 718 718 == 3.6.27 High charging current signal == 719 719 720 720 To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 721 721 780 +[[image:1732215211714-445.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="181" width="322"]] 722 722 723 723 In this section: 724 724 ... ... @@ -737,12 +737,16 @@ 737 737 738 738 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 739 739 799 +(% class="box infomessage" %) 800 +((( 740 740 The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 802 +))) 741 741 742 742 == 3.6.28 Heater control == 743 743 744 744 To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 745 745 808 +[[image:1732215252650-791.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="233" width="370"]] 746 746 747 747 In this section: 748 748 ... ... @@ -766,7 +766,7 @@ 766 766 767 767 (% class="box infomessage" %) 768 768 ((( 769 -If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 832 +If there is the "Heater" signal, the **heater **relay closes and/or a signal is output to the corresponded digital output. 770 770 ))) 771 771 772 772 == 3.6.29 Heater (AUX) control == ... ... @@ -773,6 +773,7 @@ 773 773 774 774 To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 775 775 839 +[[image:1732215282135-420.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="228" width="361"]] 776 776 777 777 In this section: 778 778 ... ... @@ -796,7 +796,7 @@ 796 796 797 797 (% class="box infomessage" %) 798 798 ((( 799 -If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 863 +If there is the "Heater (AUX)" signal, the **auxiliary heater **relay closes and/or a signal is output to the corresponded digital output. 800 800 ))) 801 801 802 802 == 3.6.30 Cooler control == ... ... @@ -803,6 +803,7 @@ 803 803 804 804 To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 805 805 870 +[[image:1732215313977-499.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="219" width="348"]] 806 806 807 807 In this section: 808 808 ... ... @@ -826,7 +826,7 @@ 826 826 827 827 (% class="box infomessage" %) 828 828 ((( 829 -If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 894 +If there is the "Cooler" signal, the **cooler **relay closes and/or a signal is output to the corresponded digital output. 830 830 ))) 831 831 832 832 == 3.6.31 Fault simulation == ... ... @@ -835,40 +835,6 @@ 835 835 836 836 To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 837 837 903 +[[image:1732215359330-850.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="732" width="204"]] 838 838 839 -In this section: 840 - 841 -* Overcurrent; 842 -* Undervoltage; 843 -* Overvoltage; 844 -* Low CH temperature; 845 -* Low DCH temperature; 846 -* High CH temperature; 847 -* High DCH temperature; 848 -* Battery cover error; 849 -* High humidity; 850 -* Water; 851 -* Current sensor error; 852 -* Short circuit; 853 -* Contactor high temperature; 854 -* Unallowable charging; 855 -* Stuck contactor; 856 -* CH contactor feedback error; 857 -* DCH contactor feedback error; 858 -* PCH contactor feedback error; 859 -* CH/DCH contactor feedback error; 860 -* Main contactor feedback error; 861 -* CH contactor cycles error; 862 -* DCH contactor cycles error; 863 -* Logic high temperature; 864 -* Logic offline; 865 -* Cell count error; 866 -* Logic count error; 867 -* Insulation error; 868 -* Critical error; 869 -* Low SOC; 870 -* High charging current; 871 -* Heater; 872 -* Cooler. 873 - 874 874 To simulate errors, set the necessary flags and click on the "Save" button.
- 1732214183037-761.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.7 KB - Content
- 1732214207026-822.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.8 KB - Content
- 1732214237851-405.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.6 KB - Content
- 1732214272022-547.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- 1732214367207-318.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- 1732214400721-274.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.9 KB - Content
- 1732214432750-543.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.1 KB - Content
- 1732214468462-541.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.3 KB - Content
- 1732214501360-654.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- 1732214545352-111.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- 1732214579147-515.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.5 KB - Content
- 1732214641606-453.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.8 KB - Content
- 1732214675358-202.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- 1732214703914-144.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.6 KB - Content
- 1732214731490-961.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- 1732214761141-983.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- 1732214987517-111.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.3 KB - Content
- 1732215174961-645.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 1732215211714-445.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.4 KB - Content
- 1732215252650-791.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.9 KB - Content
- 1732215282135-420.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.3 KB - Content
- 1732215313977-499.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.8 KB - Content
- 1732215359330-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.8 KB - Content