Changes for page 3.5 Battery control
Last modified by Admin on 2025/03/10 12:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - xwiki:drafts.BMS Main 2\.1.3\. Configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -1,5 +1,11 @@ 1 -== 3.5.1 Charge control == 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 2 2 4 +(% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 +== Battery control == 6 + 7 +=== Charge control === 8 + 3 3 There are two relays that serve charging the battery: a charging relay and an allow charging relay. With the help of the allow charging relay, the BMS commands the charger to start or stop charging. 4 4 5 5 The board supports two charge control algorithms: ... ... @@ -40,7 +40,7 @@ 40 40 41 41 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 42 42 43 -[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" height="725" width="471"]] 49 +[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="725" width="471"]] 44 44 45 45 In this section: 46 46 ... ... @@ -67,7 +67,7 @@ 67 67 2) the "Delay before recharging" time has passed since the opening of the allow charging relay. 68 68 ))) 69 69 70 -== 3.5.2Discharge control ==76 +=== Discharge control === 71 71 72 72 The board has a discharging relay to connect battery to the load. 73 73 ... ... @@ -110,9 +110,8 @@ 110 110 111 111 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 112 112 113 -[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" height="644" width="415"]] 119 +[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="644" width="415"]] 114 114 115 - 116 116 In this section: 117 117 118 118 * Enable – a flag to activate the discharge control; ... ... @@ -130,7 +130,7 @@ 130 130 * Voltage to clear the “Ready to discharge” signal – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 131 131 * Voltage to reset the “Ready to discharge” signal – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set. 132 132 133 -== 3.5.3Discharging (AUX) control ==138 +=== Discharging (AUX) control === 134 134 135 135 The BMS Main 2.x board can control the power supply of external equipment using the auxiliary (AUX) discharging relay. An example of external equipment can be an inverter that converts DC to AC to power a service laptop and other devices. 136 136 ... ... @@ -144,7 +144,7 @@ 144 144 145 145 To change the parameters of the powering of external equipment, select the menu "Cells → Discharging (AUX) control": 146 146 147 -[[image:1732208939544-710.png||data-xwiki-image-style-alignment="center" height="397" width="445"]] 152 +[[image:1732208939544-710.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="397" width="445"]] 148 148 149 149 In this section: 150 150 ... ... @@ -157,20 +157,19 @@ 157 157 ** Maximum voltage – maximum battery voltage, V; 158 158 * Switch off the discharging (AUX) relay on errors – the auxiliary (AUX) discharging relay opens if the following errors occur: Undervoltage, Overcurrent, High temperature (discharging), Short circuit, Critical error. 159 159 160 -== 3.5.4Charging/Discharging control ==165 +=== Charging/Discharging control === 161 161 162 162 BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as charging contactor when «Charge request» or «Charger connected» are set, otherwise – as discharging contactor. 163 163 164 164 To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control": 165 165 166 -[[image:1732209044117-558.png||data-xwiki-image-style-alignment="center" height="102" width="259"]] 171 +[[image:1732209044117-558.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="259"]] 167 167 168 - 169 169 In this section: 170 170 171 171 * Enable – a flag to enable Charging/Discharging contactor controller. 172 172 173 -== 3.5.5Main contactor ==177 +=== Main contactor === 174 174 175 175 The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor. 176 176 ... ... @@ -194,9 +194,8 @@ 194 194 195 195 To change the parameters of the main contactor, select the menu "Cells → Main contactor": 196 196 197 -[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" height="132" width="352"]] 201 +[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="132" width="352"]] 198 198 199 - 200 200 In this section: 201 201 202 202 * Enable – a flag to enable the main contactor control; ... ... @@ -203,7 +203,7 @@ 203 203 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 204 204 * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset. 205 205 206 -== 3.5.6Power down control ==209 +=== Power down control === 207 207 208 208 The BMS Main 2.x can command the BMS Power Control board to shut down the battery system if the battery voltage is low or the battery is idle for a long time. The BMS Main 2.x interacts with the BMS Power Control using the “Power down request” and the “Acknowledgement of power down” discrete signals. 209 209 ... ... @@ -216,9 +216,8 @@ 216 216 217 217 To change the parameters of the power down control, select the menu "Cells → Power down control": 218 218 219 -[[image:1732211675123-235.png||data-xwiki-image-style-alignment="center" height="198" width="402"]] 222 +[[image:1732211675123-235.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="198" width="402"]] 220 220 221 - 222 222 In this section: 223 223 224 224 * Enable – a flag to enable the power down control;