41 41  To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control":
42 42  
43 -[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" height="725" width="471"]]
43 +[[Charge control settings>>image:1732208589628-419.png||data-xwiki-image-style-alignment="center" height="725" width="471"]]
44 44  
45 45  In this section:
46 46  
... ... @@ -110,7 +110,7 @@
110 110  
111 111  To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control":
112 112  
113 -[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" height="644" width="415"]]
113 +[[Discharge control settings>>image:1732208781932-849.png||data-xwiki-image-style-alignment="center" height="644" width="415"]]
114 114  
115 115  
116 116  In this section:
... ... @@ -144,7 +144,7 @@
144 144  
145 145  To change the parameters of the powering of external equipment, select the menu "Cells → Discharging (AUX) control":
146 146  
147 -[[image:1732208939544-710.png||data-xwiki-image-style-alignment="center" height="397" width="445"]]
147 +[[Discharging (AUX) control settings>>image:1732208939544-710.png||data-xwiki-image-style-alignment="center" height="397" width="445"]]
148 148  
149 149  In this section:
150 150  
... ... @@ -163,7 +163,7 @@
163 163  
164 164  To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control":
165 165  
166 -[[image:1732209044117-558.png||data-xwiki-image-style-alignment="center" height="102" width="259"]]
166 +[[Charging/Discharging control settings>>image:1732209044117-558.png||data-xwiki-image-style-alignment="center" height="102" width="259"]]
167 167  
168 168  
169 169  In this section:
... ... @@ -170,7 +170,7 @@
170 170  
171 171  * Enable – a flag to enable Charging/Discharging contactor controller.
172 172  
173 -== 3.5.5 Main contactor ==
173 +== 3.5.5 Main contactor ==
174 174  
175 175  The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor.
176 176  
... ... @@ -194,7 +194,7 @@
194 194  
195 195  To change the parameters of the main contactor, select the menu "Cells → Main contactor":
196 196  
197 -[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" height="132" width="352"]]
197 +[[Main contactor settings>>image:1732209137414-912.png||data-xwiki-image-style-alignment="center" height="132" width="352"]]
198 198  
199 199  
200 200  In this section:
... ... @@ -202,26 +202,3 @@
202 202  * Enable – a flag to enable the main contactor control;
203 203  * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second;
204 204  * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset.
205 -
206 -== 3.5.6 Power down control ==
207 -
208 -The BMS Main 2.x can command the BMS Power Control board to shut down the battery system if the battery voltage is low or the battery is idle for a long time. The BMS Main 2.x interacts with the BMS Power Control using the “Power down request” and the “Acknowledgement of power down” discrete signals.
209 -
210 -Shutting down the battery system is performed according to the following conditions:
211 -
212 -* the battery voltage is below the minimum level;
213 -* the “Charger connected” signal is cleared for 60 seconds.
214 -
215 -The BMS Main 2.x also shuts down the battery if it stays in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” for the set time.
216 -
217 -To change the parameters of the power down control, select the menu "Cells → Power down control":
218 -
219 -[[image:1732211675123-235.png||data-xwiki-image-style-alignment="center" height="198" width="402"]]
220 -
221 -
222 -In this section:
223 -
224 -* Enable – a flag to enable the power down control;
225 -* Minimum voltage – a minimum voltage level of the battery below which the BMS commands to shut down the battery, V;
226 -* Idle time – a time of battery inactivity after which the battery is shut down, second;
227 -* Wait the "Power up/down request" signal is cleared (on startup) – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS.