Changes for page 3.5 Battery control
Last modified by Admin on 2025/03/10 12:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -drafts. bms-main-2-1.configuration.WebHome1 +xwiki:drafts.BMS Main 2\.1.configuration.WebHome - Content
-
... ... @@ -40,7 +40,7 @@ 40 40 41 41 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 42 42 43 -[[ Charge control settings>>image:1732208589628-419.png||data-xwiki-image-style-alignment="center" height="725" width="471"]]43 +[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" height="725" width="471"]] 44 44 45 45 In this section: 46 46 ... ... @@ -110,7 +110,7 @@ 110 110 111 111 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 112 112 113 -[[ Discharge control settings>>image:1732208781932-849.png||data-xwiki-image-style-alignment="center" height="644" width="415"]]113 +[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" height="644" width="415"]] 114 114 115 115 116 116 In this section: ... ... @@ -144,7 +144,7 @@ 144 144 145 145 To change the parameters of the powering of external equipment, select the menu "Cells → Discharging (AUX) control": 146 146 147 -[[ Discharging (AUX) control settings>>image:1732208939544-710.png||data-xwiki-image-style-alignment="center" height="397" width="445"]]147 +[[image:1732208939544-710.png||data-xwiki-image-style-alignment="center" height="397" width="445"]] 148 148 149 149 In this section: 150 150 ... ... @@ -163,7 +163,7 @@ 163 163 164 164 To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control": 165 165 166 -[[ Charging/Discharging control settings>>image:1732209044117-558.png||data-xwiki-image-style-alignment="center" height="102" width="259"]]166 +[[image:1732209044117-558.png||data-xwiki-image-style-alignment="center" height="102" width="259"]] 167 167 168 168 169 169 In this section: ... ... @@ -170,7 +170,7 @@ 170 170 171 171 * Enable – a flag to enable Charging/Discharging contactor controller. 172 172 173 -== 173 +== 3.5.5 Main contactor == 174 174 175 175 The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor. 176 176 ... ... @@ -194,7 +194,7 @@ 194 194 195 195 To change the parameters of the main contactor, select the menu "Cells → Main contactor": 196 196 197 -[[ Main contactor settings>>image:1732209137414-912.png||data-xwiki-image-style-alignment="center" height="132" width="352"]]197 +[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" height="132" width="352"]] 198 198 199 199 200 200 In this section: ... ... @@ -203,7 +203,7 @@ 203 203 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 204 204 * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset. 205 205 206 -== 206 +== 3.5.6 Power down control == 207 207 208 208 The BMS Main 2.x can command the BMS Power Control board to shut down the battery system if the battery voltage is low or the battery is idle for a long time. The BMS Main 2.x interacts with the BMS Power Control using the “Power down request” and the “Acknowledgement of power down” discrete signals. 209 209 ... ... @@ -216,7 +216,7 @@ 216 216 217 217 To change the parameters of the power down control, select the menu "Cells → Power down control": 218 218 219 -[[ Power down control section>>image:1732211675123-235.png||data-xwiki-image-style-alignment="center" height="198" width="402"]]219 +[[image:1732211675123-235.png||data-xwiki-image-style-alignment="center" height="198" width="402"]] 220 220 221 221 222 222 In this section: