... ... @@ -202,18 +202,3 @@
202 202  * Enable – a flag to enable the main contactor control;
203 203  * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second;
204 204  * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset.
205 -
206 -== 3.5.6 Power down control ==
207 -
208 -The BMS Main 2.x can command the BMS Power Control board to shut down the battery system if the battery voltage is low or the battery is idle for a long time. The BMS Main 2.x interacts with the BMS Power Control using the “Power down request” and the “Acknowledgement of power down” discrete signals.
209 -
210 -Shutting down the battery system is performed according to the following conditions:
211 -
212 -* the battery voltage is below the minimum level;
213 -* the “Charger connected” signal is cleared for 60 seconds.
214 -
215 -The BMS Main 2.x also shuts down the battery if it stays in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” for the set time.
216 -
217 -To change the parameters of the power down control, select the menu "Cells → Power down control":
218 -
219 -[[Power down >>image:1732211675123-235.png||data-xwiki-image-style-alignment="center" height="198" width="402"]]