Changes for page 3.5 Battery control
Last modified by Admin on 2025/03/10 12:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -202,3 +202,26 @@ 202 202 * Enable – a flag to enable the main contactor control; 203 203 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 204 204 * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset. 205 + 206 +== 3.5.6 Power down control == 207 + 208 +The BMS Main 2.x can command the BMS Power Control board to shut down the battery system if the battery voltage is low or the battery is idle for a long time. The BMS Main 2.x interacts with the BMS Power Control using the “Power down request” and the “Acknowledgement of power down” discrete signals. 209 + 210 +Shutting down the battery system is performed according to the following conditions: 211 + 212 +* the battery voltage is below the minimum level; 213 +* the “Charger connected” signal is cleared for 60 seconds. 214 + 215 +The BMS Main 2.x also shuts down the battery if it stays in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” for the set time. 216 + 217 +To change the parameters of the power down control, select the menu "Cells → Power down control": 218 + 219 +[[Power down control section>>image:1732211675123-235.png||data-xwiki-image-style-alignment="center" height="198" width="402"]] 220 + 221 + 222 +In this section: 223 + 224 +* Enable – a flag to enable the power down control; 225 +* Minimum voltage – a minimum voltage level of the battery below which the BMS commands to shut down the battery, V; 226 +* Idle time – a time of battery inactivity after which the battery is shut down, second; 227 +* Wait the "Power up/down request" signal is cleared (on startup) – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS.