Changes for page 3.5 Battery control
Last modified by Admin on 2025/03/10 12:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -drafts. bms-main-2-1.configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -40,7 +40,7 @@ 40 40 41 41 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 42 42 43 -[[ Charge control settings>>image:1732208589628-419.png||data-xwiki-image-style-alignment="center" height="725" width="471"]]43 +[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="725" width="471"]] 44 44 45 45 In this section: 46 46 ... ... @@ -110,9 +110,8 @@ 110 110 111 111 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 112 112 113 -[[ Discharge control settings>>image:1732208781932-849.png||data-xwiki-image-style-alignment="center" height="644" width="415"]]113 +[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="644" width="415"]] 114 114 115 - 116 116 In this section: 117 117 118 118 * Enable – a flag to activate the discharge control; ... ... @@ -144,7 +144,7 @@ 144 144 145 145 To change the parameters of the powering of external equipment, select the menu "Cells → Discharging (AUX) control": 146 146 147 -[[ Discharging (AUX) control settings>>image:1732208939544-710.png||data-xwiki-image-style-alignment="center" height="397" width="445"]]146 +[[image:1732208939544-710.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="397" width="445"]] 148 148 149 149 In this section: 150 150 ... ... @@ -163,14 +163,13 @@ 163 163 164 164 To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control": 165 165 166 -[[ Charging/Discharging control settings>>image:1732209044117-558.png||data-xwiki-image-style-alignment="center" height="102" width="259"]]165 +[[image:1732209044117-558.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="259"]] 167 167 168 - 169 169 In this section: 170 170 171 171 * Enable – a flag to enable Charging/Discharging contactor controller. 172 172 173 -== 171 +== 3.5.5 Main contactor == 174 174 175 175 The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor. 176 176 ... ... @@ -194,11 +194,32 @@ 194 194 195 195 To change the parameters of the main contactor, select the menu "Cells → Main contactor": 196 196 197 -[[ Main contactor settings>>image:1732209137414-912.png||data-xwiki-image-style-alignment="center" height="132" width="352"]]195 +[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="132" width="352"]] 198 198 199 - 200 200 In this section: 201 201 202 202 * Enable – a flag to enable the main contactor control; 203 203 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 204 204 * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset. 202 + 203 +== 3.5.6 Power down control == 204 + 205 +The BMS Main 2.x can command the BMS Power Control board to shut down the battery system if the battery voltage is low or the battery is idle for a long time. The BMS Main 2.x interacts with the BMS Power Control using the “Power down request” and the “Acknowledgement of power down” discrete signals. 206 + 207 +Shutting down the battery system is performed according to the following conditions: 208 + 209 +* the battery voltage is below the minimum level; 210 +* the “Charger connected” signal is cleared for 60 seconds. 211 + 212 +The BMS Main 2.x also shuts down the battery if it stays in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” for the set time. 213 + 214 +To change the parameters of the power down control, select the menu "Cells → Power down control": 215 + 216 +[[image:1732211675123-235.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="198" width="402"]] 217 + 218 +In this section: 219 + 220 +* Enable – a flag to enable the power down control; 221 +* Minimum voltage – a minimum voltage level of the battery below which the BMS commands to shut down the battery, V; 222 +* Idle time – a time of battery inactivity after which the battery is shut down, second; 223 +* Wait the "Power up/down request" signal is cleared (on startup) – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS.