... ... @@ -159,7 +159,46 @@ 159 159 160 160 == 3.5.4 Charging/Discharging control == 161 161 162 + BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as charging contactor when «Charge request» or «Charger connected» are set, otherwise – as discharging contactor. 162 162 163 -BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as charging contactor when «Charge request» or «Charger connected» are set, otherwise – as discharging contactor. 164 - 165 165 To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control": 165 + 166 +[[Charging/Discharging control settings>>image:1732209044117-558.png||data-xwiki-image-style-alignment="center" height="102" width="259"]] 167 + 168 + 169 +In this section: 170 + 171 +* Enable – a flag to enable Charging/Discharging contactor controller. 172 + 173 +== 3.5.5 Main contactor == 174 + 175 +The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor. 176 + 177 +The main contactor closes if there are no errors from the list below: 178 + 179 +* Overcurrent; 180 +* Undervoltage; 181 +* Overvoltage; 182 +* High temperature (charging); 183 +* High temperature (discharging); 184 +* Unallowable charging; 185 +* Critical error. 186 + 187 +The main contactor opens if the charging and discharging relays are opened and any of the following conditions is met: 188 + 189 +* charging or discharging current is detected during a set time; 190 +* voltage of any cell is lower than the minimum cell voltage configured in the section "Protections → Undervoltage protection" during a set time; 191 +* voltage of any cell is greater than the maximum cell voltage configured in the section "Protections → Overvoltage protection" during a set time; 192 +* temperature of any cell is greater than the maximum cell temperature configured in the section "Protections → High temperature protection" during a set time; 193 +* Critical error stays on during a set time. 194 + 195 +To change the parameters of the main contactor, select the menu "Cells → Main contactor": 196 + 197 +[[Main contactor settings>>image:1732209137414-912.png||data-xwiki-image-style-alignment="center" height="132" width="352"]] 198 + 199 + 200 +In this section: 201 + 202 +* Enable – a flag to enable the main contactor control; 203 +* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 204 +* Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset.
- 1732209137414-912.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.7 KB - Content
- 1732211675123-235.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content