Changes for page 3.5 Battery control
Last modified by Admin on 2025/08/11 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -46,7 +46,7 @@ 46 46 47 47 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 48 48 49 -[[image:175 1888542152-699.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="741" width="450"]]49 +[[image:1754929673129-253.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="755" width="450"]] 50 50 51 51 In this section: 52 52 ... ... @@ -64,10 +64,11 @@ 64 64 * Switch off the charging relay on errors without delay – a flag to protectively open the charging relay without delay. In the opposite case, when an error is detected, the charging relay opens always with the delay “Delay before stopping charging”; 65 65 * Control the precharging relay – a flag to enable control of the precharging relay at charge; 66 66 * Finish precharge if the battery current is negative – a flag to finish precharge if discharging current occures; 67 +* Use actual voltage to generate the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal; 68 +* Use actual voltage to generate the "Ready to charge" signal if the current is negative – a flag to disable voltage correction for "Ready to charge" signal only at discharging current; 67 67 * Voltage to clear the “Ready to charge” (hence, the “Allow charging”) signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” signal is cleared; 68 68 * Voltage to reset the “Ready to charge” (hence, the “Allow charging”) signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” signal is set; 69 -* Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 70 -* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current. 71 +* Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. 71 71 72 72 (% class="box infomessage" %) 73 73 ((( ... ... @@ -119,7 +119,7 @@ 119 119 120 120 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 121 121 122 -[[image:175 1888641902-420.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="864" width="450"]]123 +[[image:1754929793688-400.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 123 123 124 124 In this section: 125 125 ... ... @@ -143,9 +143,10 @@ 143 143 * Finish precharge if the battery current is positive – a flag to finish precharge if charging current occures; 144 144 * Delay before clearing the "Precharge error", second; 145 145 * Lock the "Precharge error" until the device is reset; 147 +* Use actual voltage to generate the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal; 148 +* Use actual voltage to generate the "Ready to discharge" signal if the current is positive – a flag to disable voltage correction for "Ready to discharge" signal only at charging current; 146 146 * Voltage to clear the “Ready to discharge” signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 147 -* Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 148 -* Treat positive currents as zero currents for generating the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal at charging current. 150 +* Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set. 149 149 150 150 === Discharging (AUX) control === 151 151
- 1754929793688-400.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.9 KB - Content
- 1754930037744-556.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.3 KB - Content