Changes for page 3.5 Battery control

Last modified by Admin on 2025/07/07 11:46

From version 34.3
edited by Admin
on 2025/07/07 11:43
Change comment: There is no comment for this version
To version 36.1
edited by Admin
on 2025/07/07 11:44
Change comment: Uploaded new attachment "1751888641902-420.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -63,7 +63,7 @@
63 63  * Use specific delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
64 64  * Switch off the charging relay on errors without delay – a flag to protectively open the charging relay without delay. In the opposite case, when an error is detected, the charging relay opens always with the delay “Delay before stopping charging”;
65 65  * Control the precharging relay – a flag to enable control of the precharging relay at charge;
66 -* Finish precharge if the battery current is negative – a flag to finish precharge if there is a discharg
66 +* Finish precharge if the battery current is negative – a flag to finish precharge if discharging current occures;
67 67  * Voltage to clear the “Ready to charge” (hence, the “Allow charging”) signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” signal is cleared;
68 68  * Voltage to reset the “Ready to charge” (hence, the “Allow charging”) signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” signal is set;
69 69  * Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;
1751888641902-420.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content