Changes for page 3.5 Battery control

Last modified by Admin on 2025/07/07 11:46

From version 34.2
edited by Admin
on 2025/07/07 11:43
Change comment: There is no comment for this version
To version 33.1
edited by Admin
on 2025/07/07 11:41
Change comment: Загрузить новое вложение 1751888464334-818.png

Summary

Details

Page properties
Content
... ... @@ -46,11 +46,10 @@
46 46  
47 47  To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control":
48 48  
49 -[[image:1751888542152-699.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="741" width="450"]]
50 50  
51 51  In this section:
52 52  
53 -* Enable – a flag to activate the charge control;
52 +* Enable – a flag to activate the charge control;[[image:1749655182004-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="687" width="431"]]
54 54  * Charging algorithm:
55 55  ** Always on – charging is always allowed;
56 56  ** On charger connected – charging is allowed when there is a signal “Charger connected”;
... ... @@ -63,7 +63,6 @@
63 63  * Use specific delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
64 64  * Switch off the charging relay on errors without delay – a flag to protectively open the charging relay without delay. In the opposite case, when an error is detected, the charging relay opens always with the delay “Delay before stopping charging”;
65 65  * Control the precharging relay – a flag to enable control of the precharging relay at charge;
66 -* Finish precharge if the battery current is negative – a flag to finish precharge if there is a
67 67  * Voltage to clear the “Ready to charge” (hence, the “Allow charging”) signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” signal is cleared;
68 68  * Voltage to reset the “Ready to charge” (hence, the “Allow charging”) signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” signal is set;
69 69  * Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;
1751888542152-699.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -59.1 KB
Content