Changes for page 3.5 Battery control
Last modified by Admin on 2025/07/07 11:46
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -46,10 +46,11 @@ 46 46 47 47 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 48 48 49 +[[image:1751888542152-699.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="741" width="450"]] 49 49 50 50 In this section: 51 51 52 -* Enable – a flag to activate the charge control; [[image:1749655182004-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="687" width="431"]]53 +* Enable – a flag to activate the charge control; 53 53 * Charging algorithm: 54 54 ** Always on – charging is always allowed; 55 55 ** On charger connected – charging is allowed when there is a signal “Charger connected”; ... ... @@ -62,6 +62,7 @@ 62 62 * Use specific delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 63 63 * Switch off the charging relay on errors without delay – a flag to protectively open the charging relay without delay. In the opposite case, when an error is detected, the charging relay opens always with the delay “Delay before stopping charging”; 64 64 * Control the precharging relay – a flag to enable control of the precharging relay at charge; 66 +* Finish precharge if the battery current is negative – a flag to finish precharge if discharging current occures; 65 65 * Voltage to clear the “Ready to charge” (hence, the “Allow charging”) signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” signal is cleared; 66 66 * Voltage to reset the “Ready to charge” (hence, the “Allow charging”) signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” signal is set; 67 67 * Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; ... ... @@ -117,7 +117,7 @@ 117 117 118 118 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 119 119 120 -[[image:17 49654838818-400.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="828" width="446"]]122 +[[image:1751888641902-420.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="864" width="450"]] 121 121 122 122 In this section: 123 123 ... ... @@ -138,6 +138,7 @@ 138 138 * Precharge time – a duration of closing the precharge relay before closing the discharging relay, millisecond; 139 139 * Precharge current threshold to start discharging – a minimum current value to finish precharging and start discharge, A; 140 140 * Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay; 143 +* Finish precharge if the battery current is positive – a flag to finish precharge if charging current occures; 141 141 * Delay before clearing the "Precharge error", second; 142 142 * Lock the "Precharge error" until the device is reset; 143 143 * Voltage to clear the “Ready to discharge” signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
- 1751888641902-420.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.5 KB - Content
- 1751888697899-848.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.1 KB - Content