Changes for page 3.5 Battery control
Last modified by Admin on 2025/06/19 10:26
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -65,7 +65,7 @@ 65 65 * Voltage to clear the “Ready to charge” (hence, the “Allow charging”) signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” signal is cleared; 66 66 * Voltage to reset the “Ready to charge” (hence, the “Allow charging”) signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” signal is set; 67 67 * Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 68 -* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current.68 +* Treat positive currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current; 69 69 70 70 (% class="box infomessage" %) 71 71 ((( ... ... @@ -134,7 +134,7 @@ 134 134 * Use specific delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 135 135 * Switch off the discharging relay on errors without delay – a flag to protectively open the discharging relay without delay. In the opposite case, when an error is detected, the discharging relay opens always with the delay “Delay before stopping discharging”. 136 136 * Control the precharging relay – a flag to enable precharge at discharging; 137 -* Delay before current measurement – a delay before first current measurement after closing precharge, millisecond;137 +* Delay before current measurement, millisecond; 138 138 * Precharge time – a duration of closing the precharge relay before closing the discharging relay, millisecond; 139 139 * Precharge current threshold to start discharging – a minimum current value to finish precharging and start discharge, A; 140 140 * Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay; ... ... @@ -142,7 +142,7 @@ 142 142 * Lock the "Precharge error" until the device is reset; 143 143 * Voltage to clear the “Ready to discharge” signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 144 144 * Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 145 -* Treat positive currents as zero currents for generating the "Ready todischarge" signal – a flag to disable voltage correction for "Ready todischarge" signal at charging current.145 +* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current. 146 146 147 147 === Discharging (AUX) control === 148 148