Changes for page 3.5 Battery control
Last modified by Admin on 2025/06/18 15:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -142,7 +142,7 @@ 142 142 * Lock the "Precharge error" until the device is reset; 143 143 * Voltage to clear the “Ready to discharge” signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 144 144 * Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 145 -* Treat positive currents as zero currents for generating the "Ready todischarge" signal – a flag to disable voltage correction for "Ready todischarge" signal at charging current.145 +* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current. 146 146 147 147 === Discharging (AUX) control === 148 148