Changes for page 3.5 Battery control
Last modified by Admin on 2025/06/11 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -46,10 +46,11 @@ 46 46 47 47 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 48 48 49 +[[image:1739961593607-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="639" width="425"]] 49 49 50 50 In this section: 51 51 52 -* Enable – a flag to activate the charge control; [[image:1749655182004-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="687" width="431"]]53 +* Enable – a flag to activate the charge control; 53 53 * Charging algorithm: 54 54 ** Always on – charging is always allowed; 55 55 ** On charger connected – charging is allowed when there is a signal “Charger connected”; ... ... @@ -61,11 +61,10 @@ 61 61 * Delay before stopping charging – a time delay T,,off,, before opening the charging relay, second; 62 62 * Use specific delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 63 63 * Switch off the charging relay on errors without delay – a flag to protectively open the charging relay without delay. In the opposite case, when an error is detected, the charging relay opens always with the delay “Delay before stopping charging”; 64 -* Control the precharging relay – a flag t oenablecontrol of the precharging relayat charge;65 +* Control the precharging relay – a flag that allows control of the precharging relay; 65 65 * Voltage to clear the “Ready to charge” (hence, the “Allow charging”) signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” signal is cleared; 66 66 * Voltage to reset the “Ready to charge” (hence, the “Allow charging”) signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” signal is set; 67 -* Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 68 -* Treat poive currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current; 68 +* Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. 69 69 70 70 (% class="box infomessage" %) 71 71 ((( ... ... @@ -138,11 +138,11 @@ 138 138 * Precharge time – a duration of closing the precharge relay before closing the discharging relay, millisecond; 139 139 * Precharge current threshold to start discharging – a minimum current value to finish precharging and start discharge, A; 140 140 * Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay; 141 -* Delay before clearing the "Precharge error", second ;142 -* Lock the "Precharge error" until the device is reset ;141 +* Delay before clearing the "Precharge error", second – 142 +* Lock the "Precharge error" until the device is reset 143 143 * Voltage to clear the “Ready to discharge” signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 144 144 * Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 145 -* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current .145 +* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current; 146 146 147 147 === Discharging (AUX) control === 148 148