47 47  To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control":
48 48  
49 -[[image:1739961593607-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="639" width="425"]]
50 50  
51 51  In this section:
52 52  
53 -* Enable – a flag to activate the charge control;
52 +* Enable – a flag to activate the charge control;[[image:1749655182004-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="687" width="431"]]
54 54  * Charging algorithm:
55 55  ** Always on – charging is always allowed;
56 56  ** On charger connected – charging is allowed when there is a signal “Charger connected”;
... ... @@ -62,10 +62,11 @@
62 62  * Delay before stopping charging – a time delay T,,off,, before opening the charging relay, second;
63 63  * Use specific delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
64 64  * Switch off the charging relay on errors without delay – a flag to protectively open the charging relay without delay. In the opposite case, when an error is detected, the charging relay opens always with the delay “Delay before stopping charging”;
65 -* Control the precharging relay – a flag that allows control of the precharging relay;
64 +* Control the precharging relay – a flag to enable control of the precharging relay at charge;
66 66  * Voltage to clear the “Ready to charge” (hence, the “Allow charging”) signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” signal is cleared;
67 67  * Voltage to reset the “Ready to charge” (hence, the “Allow charging”) signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” signal is set;
68 -* Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0.
67 +* Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;
68 +* Treat positive currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current;
69 69  
70 70  (% class="box infomessage" %)
71 71  (((
... ... @@ -138,11 +138,11 @@
138 138  * Precharge time – a duration of closing the precharge relay before closing the discharging relay, millisecond;
139 139  * Precharge current threshold to start discharging – a minimum current value to finish precharging and start discharge, A;
140 140  * Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay;
141 -* Delay before clearing the "Precharge error", second
142 -* Lock the "Precharge error" until the device is reset
141 +* Delay before clearing the "Precharge error", second;
142 +* Lock the "Precharge error" until the device is reset;
143 143  * Voltage to clear the “Ready to discharge” signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
144 144  * Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;
145 -* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current;
145 +* Treat negative currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current.
146 146  
147 147  === Discharging (AUX) control ===
148 148  
1749655182004-633.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +50.0 KB
Content