Changes for page 3.5 Battery control

Last modified by Admin on 2025/06/11 15:20

From version 26.5
edited by Admin
on 2025/06/11 15:19
Change comment: There is no comment for this version
To version 26.6
edited by Admin
on 2025/06/11 15:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -138,7 +138,7 @@
138 138  * Precharge time – a duration of closing the precharge relay before closing the discharging relay, millisecond;
139 139  * Precharge current threshold to start discharging – a minimum current value to finish precharging and start discharge, A;
140 140  * Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay;
141 -* Delay before clearing the "Precharge error", second – a
141 +* Delay before clearing the "Precharge error", second –
142 142  * Lock the "Precharge error" until the device is reset
143 143  * Voltage to clear the “Ready to discharge” signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
144 144  * Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;