Changes for page 3.5 Battery control

Last modified by Admin on 2025/03/10 12:50

From version 25.1
edited by Admin
on 2025/03/10 12:50
Change comment: There is no comment for this version
To version 22.1
edited by Admin
on 2025/02/19 10:41
Change comment: Загрузить новое вложение 1739961703149-845.png

Summary

Details

Page properties
Content
... ... @@ -4,7 +4,7 @@
4 4  (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == Battery control ==
6 6  
7 -=== Charging control ===
7 +=== Charge control ===
8 8  
9 9  There are two relays that serve charging the battery: a charging relay and an allow charging relay. With the help of the allow charging relay, the BMS commands the charger to start or stop charging.
10 10  
... ... @@ -46,7 +46,7 @@
46 46  
47 47  To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control":
48 48  
49 -[[image:1739961593607-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="639" width="425"]]
49 +[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="725" width="471"]]
50 50  
51 51  In this section:
52 52  
... ... @@ -55,7 +55,6 @@
55 55  ** Always on – charging is always allowed;
56 56  ** On charger connected – charging is allowed when there is a signal “Charger connected”;
57 57  ** On charge request – charging is allowed when there is a signal “Charge request”;
58 -* Allow charging only when the "Ready to charge" signal is set;
59 59  * Current indicating charging – a current level to generate the "Charging current present" signal, A;
60 60  * Current indicating no charging – a current level to clear the "Charging current present" signal, A;
61 61  * Delay before starting charging – a time delay T,,on,, before closing the charging relay and the allow charging relay, second;
... ... @@ -74,7 +74,7 @@
74 74  2) the "Delay before recharging" time has passed since the opening of the allow charging relay.
75 75  )))
76 76  
77 -=== Discharging control ===
76 +=== Discharge control ===
78 78  
79 79  The board has a discharging relay to connect battery to the load.
80 80  
... ... @@ -117,7 +117,7 @@
117 117  
118 118  To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control":
119 119  
120 -[[image:1739961703149-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="748" width="440"]]
119 +[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="644" width="415"]]
121 121  
122 122  In this section:
123 123  
... ... @@ -126,7 +126,6 @@
126 126  ** Always on – load is always connected;
127 127  ** On charger disconnected – load is connected when there is no signal “Charger connected”;
128 128  ** On discharge request – load is connected when there is a signal “Discharge request”;
129 -* Allow discharging only when the "Ready to discharge" signal is set;
130 130  * Current indicating discharging – a current level to generate the "Discharging current present" signal, А;
131 131  * Current indicating no discharging – a current level to clear the "Discharging current present" signal, А;
132 132  * Delay before starting discharging – a time delay T,,on,, before closing the discharging relay, second;
... ... @@ -170,7 +170,7 @@
170 170  
171 171  === Charging/Discharging control ===
172 172  
173 - BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as [[charging>>doc:||anchor="HChargingcontrol"]] contactor when «Charge request» or «Charger connected» are set, otherwise – as [[discharging>>doc:||anchor="HDischargingcontrol"]] contactor.
171 + BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as charging contactor when «Charge request» or «Charger connected» are set, otherwise – as discharging contactor.
174 174  
175 175  To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control":
176 176