Changes for page 3.5 Battery control
Last modified by Admin on 2025/06/11 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Battery control == 6 6 7 -=== Charg econtrol ===7 +=== Charging control === 8 8 9 9 There are two relays that serve charging the battery: a charging relay and an allow charging relay. With the help of the allow charging relay, the BMS commands the charger to start or stop charging. 10 10 ... ... @@ -74,7 +74,7 @@ 74 74 2) the "Delay before recharging" time has passed since the opening of the allow charging relay. 75 75 ))) 76 76 77 -=== Discharg econtrol ===77 +=== Discharging control === 78 78 79 79 The board has a discharging relay to connect battery to the load. 80 80 ... ... @@ -117,7 +117,7 @@ 117 117 118 118 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 119 119 120 -[[image:17 39961703149-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="748" width="440"]]120 +[[image:1749654838818-400.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="828" width="446"]] 121 121 122 122 In this section: 123 123 ... ... @@ -136,7 +136,8 @@ 136 136 * Precharge time – a duration of closing the precharge relay before closing the discharging relay, millisecond; 137 137 * Precharge current threshold to start discharging – a minimum current value to finish precharging and start discharge, A; 138 138 * Voltage to clear the “Ready to discharge” signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 139 -* Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set. 139 +* Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 140 +* Treat negative currents as zero currents for generating the "Read y to charge" signal – a flag to disable voltage correction 140 140 141 141 === Discharging (AUX) control === 142 142 ... ... @@ -170,7 +170,7 @@ 170 170 171 171 === Charging/Discharging control === 172 172 173 - BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as charging 174 + BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as [[charging>>doc:||anchor="HChargingcontrol"]] contactor when «Charge request» or «Charger connected» are set, otherwise – as [[discharging>>doc:||anchor="HDischargingcontrol"]] contactor. 174 174 175 175 To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control": 176 176
- 1749654838818-400.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.9 KB - Content