Changes for page 3.5 Battery control

Last modified by Admin on 2025/03/10 12:50

From version 24.1
edited by Admin
on 2025/02/19 10:43
Change comment: There is no comment for this version
To version 22.1
edited by Admin
on 2025/02/19 10:41
Change comment: Загрузить новое вложение 1739961703149-845.png

Summary

Details

Page properties
Content
... ... @@ -46,7 +46,7 @@
46 46  
47 47  To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control":
48 48  
49 -[[image:1739961593607-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="639" width="425"]]
49 +[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="725" width="471"]]
50 50  
51 51  In this section:
52 52  
... ... @@ -55,7 +55,6 @@
55 55  ** Always on – charging is always allowed;
56 56  ** On charger connected – charging is allowed when there is a signal “Charger connected”;
57 57  ** On charge request – charging is allowed when there is a signal “Charge request”;
58 -* Allow charging only when the "Ready to charge" signal is set;
59 59  * Current indicating charging – a current level to generate the "Charging current present" signal, A;
60 60  * Current indicating no charging – a current level to clear the "Charging current present" signal, A;
61 61  * Delay before starting charging – a time delay T,,on,, before closing the charging relay and the allow charging relay, second;
... ... @@ -117,7 +117,7 @@
117 117  
118 118  To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control":
119 119  
120 -[[image:1739961703149-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="748" width="440"]]
119 +[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="644" width="415"]]
121 121  
122 122  In this section:
123 123  
... ... @@ -126,7 +126,6 @@
126 126  ** Always on – load is always connected;
127 127  ** On charger disconnected – load is connected when there is no signal “Charger connected”;
128 128  ** On discharge request – load is connected when there is a signal “Discharge request”;
129 -* Allow discharging only when the "Ready to discharge" signal is set;
130 130  * Current indicating discharging – a current level to generate the "Discharging current present" signal, А;
131 131  * Current indicating no discharging – a current level to clear the "Discharging current present" signal, А;
132 132  * Delay before starting discharging – a time delay T,,on,, before closing the discharging relay, second;