... ... @@ -46,7 +46,7 @@ 46 46 47 47 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 48 48 49 -[[image:173 9961593607-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="639" width="425"]]49 +[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="725" width="471"]] 50 50 51 51 In this section: 52 52 ... ... @@ -55,7 +55,6 @@ 55 55 ** Always on – charging is always allowed; 56 56 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 57 57 ** On charge request – charging is allowed when there is a signal “Charge request”; 58 -* Allow charging only when the "Ready to charge" signal is set; 59 59 * Current indicating charging – a current level to generate the "Charging current present" signal, A; 60 60 * Current indicating no charging – a current level to clear the "Charging current present" signal, A; 61 61 * Delay before starting charging – a time delay T,,on,, before closing the charging relay and the allow charging relay, second; ... ... @@ -111,13 +111,13 @@ 111 111 **Note:** In case of errors in the system operation, the opening of the discharging relay is performed either immediately or with a delay T,,off,, (depends on the settings described below). 112 112 ))) 113 113 114 -The board supports controlling the precharging relay. The duration of switching on the precharging relay and precharge current thresholdbefore closing the discharging (load) relayareadjustable.113 +The board supports controlling the precharging relay. The duration of switching on the precharging relay before closing the discharging (load) relay is adjusted. 115 115 116 116 When the power down request occurs, the discharging relay opens after delay T,,off,,. Reclosing the discharging relay is performed if the power down request is removed. 117 117 118 118 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 119 119 120 -[[image:173 9961703149-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="748" width="440"]]119 +[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="644" width="415"]] 121 121 122 122 In this section: 123 123 ... ... @@ -126,7 +126,6 @@ 126 126 ** Always on – load is always connected; 127 127 ** On charger disconnected – load is connected when there is no signal “Charger connected”; 128 128 ** On discharge request – load is connected when there is a signal “Discharge request”; 129 -* Allow discharging only when the "Ready to discharge" signal is set; 130 130 * Current indicating discharging – a current level to generate the "Discharging current present" signal, А; 131 131 * Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 132 132 * Delay before starting discharging – a time delay T,,on,, before closing the discharging relay, second; ... ... @@ -207,7 +207,7 @@ 207 207 * Other contactors are open; 208 208 * There is an error from the the list above. 209 209 210 -In “Automatic” mode, the main contactor closes and opensby internal algorithms at the same time with other contactors.208 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 211 211 212 212 In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 213 213
- 1739961593607-309.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -53.5 KB - Content
- 1739961703149-845.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -60.6 KB - Content