Changes for page 3.5 Battery control
Last modified by Admin on 2025/03/10 12:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -46,7 +46,7 @@ 46 46 47 47 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 48 48 49 -[[image:173 2208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="725" width="471"]]49 +[[image:1739961593607-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="639" width="425"]] 50 50 51 51 In this section: 52 52 ... ... @@ -55,6 +55,7 @@ 55 55 ** Always on – charging is always allowed; 56 56 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 57 57 ** On charge request – charging is allowed when there is a signal “Charge request”; 58 +* Allow charging only when the "Ready to charge" signal is set; 58 58 * Current indicating charging – a current level to generate the "Charging current present" signal, A; 59 59 * Current indicating no charging – a current level to clear the "Charging current present" signal, A; 60 60 * Delay before starting charging – a time delay T,,on,, before closing the charging relay and the allow charging relay, second; ... ... @@ -116,7 +116,7 @@ 116 116 117 117 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 118 118 119 -[[image:173 2208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="644" width="415"]]120 +[[image:1739961703149-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="748" width="440"]] 120 120 121 121 In this section: 122 122 ... ... @@ -125,6 +125,7 @@ 125 125 ** Always on – load is always connected; 126 126 ** On charger disconnected – load is connected when there is no signal “Charger connected”; 127 127 ** On discharge request – load is connected when there is a signal “Discharge request”; 129 +* Allow discharging only when the "Ready to discharge" signal is set; 128 128 * Current indicating discharging – a current level to generate the "Discharging current present" signal, А; 129 129 * Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 130 130 * Delay before starting discharging – a time delay T,,on,, before closing the discharging relay, second;