Changes for page 3.5 Battery control
Last modified by Admin on 2025/03/10 12:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -46,7 +46,7 @@ 46 46 47 47 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 48 48 49 -[[image:173 2208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="725" width="471"]]49 +[[image:1739961593607-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="639" width="425"]] 50 50 51 51 In this section: 52 52 ... ... @@ -55,6 +55,7 @@ 55 55 ** Always on – charging is always allowed; 56 56 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 57 57 ** On charge request – charging is allowed when there is a signal “Charge request”; 58 +* Allow charging only when the "Ready to charge" signal is set; 58 58 * Current indicating charging – a current level to generate the "Charging current present" signal, A; 59 59 * Current indicating no charging – a current level to clear the "Charging current present" signal, A; 60 60 * Delay before starting charging – a time delay T,,on,, before closing the charging relay and the allow charging relay, second; ... ... @@ -110,13 +110,13 @@ 110 110 **Note:** In case of errors in the system operation, the opening of the discharging relay is performed either immediately or with a delay T,,off,, (depends on the settings described below). 111 111 ))) 112 112 113 -The board supports controlling the precharging relay. The duration of switching on the precharging relay before closing the discharging (load) relay isadjusted.114 +The board supports controlling the precharging relay. The duration of switching on the precharging relay and precharge current threshold before closing the discharging (load) relay are adjustable. 114 114 115 115 When the power down request occurs, the discharging relay opens after delay T,,off,,. Reclosing the discharging relay is performed if the power down request is removed. 116 116 117 117 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 118 118 119 -[[image:173 2208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="644" width="415"]]120 +[[image:1739961703149-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="748" width="440"]] 120 120 121 121 In this section: 122 122 ... ... @@ -125,6 +125,7 @@ 125 125 ** Always on – load is always connected; 126 126 ** On charger disconnected – load is connected when there is no signal “Charger connected”; 127 127 ** On discharge request – load is connected when there is a signal “Discharge request”; 129 +* Allow discharging only when the "Ready to discharge" signal is set; 128 128 * Current indicating discharging – a current level to generate the "Discharging current present" signal, А; 129 129 * Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 130 130 * Delay before starting discharging – a time delay T,,on,, before closing the discharging relay, second;
- 1739961593607-309.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.5 KB - Content
- 1739961703149-845.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.6 KB - Content