... ... @@ -110,7 +110,7 @@ 110 110 **Note:** In case of errors in the system operation, the opening of the discharging relay is performed either immediately or with a delay T,,off,, (depends on the settings described below). 111 111 ))) 112 112 113 -The board supports controlling the precharging relay. The duration of switching on the precharging relay before closing the discharging (load) relay isadjusted.113 +The board supports controlling the precharging relay. The duration of switching on the precharging relay and precharge current threshold before closing the discharging (load) relay are adjustable. 114 114 115 115 When the power down request occurs, the discharging relay opens after delay T,,off,,. Reclosing the discharging relay is performed if the power down request is removed. 116 116 ... ... @@ -205,7 +205,7 @@ 205 205 * Other contactors are open; 206 206 * There is an error from the the list above. 207 207 208 -In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 208 +In “Automatic” mode, the main contactor closes and opens by internal algorithms at the same time with other contactors. 209 209 210 210 In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 211 211