... ... @@ -182,44 +182,31 @@ 182 182 183 183 The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor. 184 184 185 -The Main contactoralgorithmsupports thefollowingmodes:185 +The main contactor closes if there are no errors from the list below: 186 186 187 -* Always on; 188 -* Automatic; 189 -* On demand. 187 +* Overcurrent; 188 +* Undervoltage; 189 +* Overvoltage; 190 +* High temperature (charging); 191 +* High temperature (discharging); 192 +* Unallowable charging; 193 +* Critical error. 190 190 191 - In “Always on” mode main contactorcloses if allthe following istrue:195 +The main contactor opens if the charging and discharging relays are opened and any of the following conditions is met: 192 192 193 -* Other contactors are open; 194 -* There are no errors from the list below: 195 -** Overcurrent; 196 -** Undervoltage; 197 -** Overvoltage; 198 -** High temperature (charging); 199 -** High temperature (discharging); 200 -** Unallowable charging; 201 -** Critical error. 197 +* charging or discharging current is detected during a set time; 198 +* voltage of any cell is lower than the minimum cell voltage configured in the section "Protections → Undervoltage protection" during a set time; 199 +* voltage of any cell is greater than the maximum cell voltage configured in the section "Protections → Overvoltage protection" during a set time; 200 +* temperature of any cell is greater than the maximum cell temperature configured in the section "Protections → High temperature protection" during a set time; 201 +* Critical error stays on during a set time. 202 202 203 -In “Always on” mode main contactor opens if all the following is true: 204 - 205 -* Other contactors are open; 206 -* There is an error from the the list above. 207 - 208 -In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 209 - 210 -In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 211 - 212 212 To change the parameters of the main contactor, select the menu "Cells → Main contactor": 213 213 214 -[[image:173 9958553206-813.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="410"]]205 +[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="132" width="352"]] 215 215 216 216 In this section: 217 217 218 218 * Enable – a flag to enable the main contactor control; 219 -* Algorithm – main contactor control algorithm: 220 -** Always on – contactor is always closed; 221 -** Automatic – contactor closes by internal charge and discharge algorithms; 222 -** On demand – contactor is closed by an external request; 223 223 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 224 224 * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset. 225 225
- 1739958553206-813.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -11.6 KB - Content