Changes for page 3.5 Battery control
Last modified by Admin on 2025/03/10 12:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Battery control == 6 6 7 -=== Charg econtrol ===7 +=== Charging control === 8 8 9 9 There are two relays that serve charging the battery: a charging relay and an allow charging relay. With the help of the allow charging relay, the BMS commands the charger to start or stop charging. 10 10 ... ... @@ -46,7 +46,7 @@ 46 46 47 47 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 48 48 49 -[[image:173 2208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="725" width="471"]]49 +[[image:1739961593607-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="639" width="425"]] 50 50 51 51 In this section: 52 52 ... ... @@ -55,6 +55,7 @@ 55 55 ** Always on – charging is always allowed; 56 56 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 57 57 ** On charge request – charging is allowed when there is a signal “Charge request”; 58 +* Allow charging only when the "Ready to charge" signal is set; 58 58 * Current indicating charging – a current level to generate the "Charging current present" signal, A; 59 59 * Current indicating no charging – a current level to clear the "Charging current present" signal, A; 60 60 * Delay before starting charging – a time delay T,,on,, before closing the charging relay and the allow charging relay, second; ... ... @@ -73,7 +73,7 @@ 73 73 2) the "Delay before recharging" time has passed since the opening of the allow charging relay. 74 74 ))) 75 75 76 -=== Discharg econtrol ===77 +=== Discharging control === 77 77 78 78 The board has a discharging relay to connect battery to the load. 79 79 ... ... @@ -110,13 +110,13 @@ 110 110 **Note:** In case of errors in the system operation, the opening of the discharging relay is performed either immediately or with a delay T,,off,, (depends on the settings described below). 111 111 ))) 112 112 113 -The board supports controlling the precharging relay. The duration of switching on the precharging relay before closing the discharging (load) relay isadjusted.114 +The board supports controlling the precharging relay. The duration of switching on the precharging relay and precharge current threshold before closing the discharging (load) relay are adjustable. 114 114 115 115 When the power down request occurs, the discharging relay opens after delay T,,off,,. Reclosing the discharging relay is performed if the power down request is removed. 116 116 117 117 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 118 118 119 -[[image:173 2208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="644" width="415"]]120 +[[image:1739961703149-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="748" width="440"]] 120 120 121 121 In this section: 122 122 ... ... @@ -125,6 +125,7 @@ 125 125 ** Always on – load is always connected; 126 126 ** On charger disconnected – load is connected when there is no signal “Charger connected”; 127 127 ** On discharge request – load is connected when there is a signal “Discharge request”; 129 +* Allow discharging only when the "Ready to discharge" signal is set; 128 128 * Current indicating discharging – a current level to generate the "Discharging current present" signal, А; 129 129 * Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 130 130 * Delay before starting discharging – a time delay T,,on,, before closing the discharging relay, second; ... ... @@ -168,7 +168,7 @@ 168 168 169 169 === Charging/Discharging control === 170 170 171 - BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as charging 173 + BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as [[charging>>doc:||anchor="HChargingcontrol"]] contactor when «Charge request» or «Charger connected» are set, otherwise – as [[discharging>>doc:||anchor="HDischargingcontrol"]] contactor. 172 172 173 173 To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control": 174 174 ... ... @@ -182,30 +182,33 @@ 182 182 183 183 The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor. 184 184 185 -The main contactorclosesifthereare noerrorsfromthe list below:187 +The Main contactor algorithm supports the following modes: 186 186 187 -* Overcurrent; 188 -* Undervoltage; 189 -* Overvoltage; 190 -* High temperature (charging); 191 -* High temperature (discharging); 192 -* Unallowable charging; 193 -* Critical error. 189 +* Always on; 190 +* Automatic; 191 +* On demand. 194 194 195 - The main contactor opens ifthe charging and discharging relaysare opened and any ofthe followingconditionsis met:193 +In “Always on” mode main contactor closes if all the following is true: 196 196 197 -* charging or discharging current is detected during a set time; 198 -* voltage of any cell is lower than the minimum cell voltage configured in the section "Protections → Undervoltage protection" during a set time; 199 -* voltage of any cell is greater than the maximum cell voltage configured in the section "Protections → Overvoltage protection" during a set time; 200 -* temperature of any cell is greater than the maximum cell temperature configured in the section "Protections → High temperature protection" during a set time; 201 -* Critical error stays on during a set time. 195 +* Other contactors are open; 196 +* There are no errors from the list below: 197 +** Overcurrent; 198 +** Undervoltage; 199 +** Overvoltage; 200 +** High temperature (charging); 201 +** High temperature (discharging); 202 +** Unallowable charging; 203 +** Critical error. 202 202 203 - TheMain contactoralgorithm supports the followingmodes:205 +In “Always on” mode main contactor opens if all the following is true: 204 204 205 -* 206 -* Automatic; 207 -* On demand. 207 +* Other contactors are open; 208 +* There is an error from the the list above. 208 208 210 +In “Automatic” mode, the main contactor closes and opens by internal algorithms at the same time with other contactors. 211 + 212 +In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 213 + 209 209 To change the parameters of the main contactor, select the menu "Cells → Main contactor": 210 210 211 211 [[image:1739958553206-813.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="410"]] ... ... @@ -213,6 +213,10 @@ 213 213 In this section: 214 214 215 215 * Enable – a flag to enable the main contactor control; 221 +* Algorithm – main contactor control algorithm: 222 +** Always on – contactor is always closed; 223 +** Automatic – contactor closes by internal charge and discharge algorithms; 224 +** On demand – contactor is closed by an external request; 216 216 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 217 217 * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset. 218 218
- 1739961593607-309.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.5 KB - Content
- 1739961703149-845.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.6 KB - Content