... ... @@ -182,31 +182,44 @@ 182 182 183 183 The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor. 184 184 185 -The main contactorclosesifthereare noerrorsfromthe list below:185 +The Main contactor algorithm supports the following modes: 186 186 187 -* Overcurrent; 188 -* Undervoltage; 189 -* Overvoltage; 190 -* High temperature (charging); 191 -* High temperature (discharging); 192 -* Unallowable charging; 193 -* Critical error. 187 +* Always on; 188 +* Automatic; 189 +* On demand. 194 194 195 - The main contactor opens ifthe charging and discharging relaysare opened and any ofthe followingconditionsis met:191 +In “Always on” mode main contactor closes if all the following is true: 196 196 197 -* charging or discharging current is detected during a set time; 198 -* voltage of any cell is lower than the minimum cell voltage configured in the section "Protections → Undervoltage protection" during a set time; 199 -* voltage of any cell is greater than the maximum cell voltage configured in the section "Protections → Overvoltage protection" during a set time; 200 -* temperature of any cell is greater than the maximum cell temperature configured in the section "Protections → High temperature protection" during a set time; 201 -* Critical error stays on during a set time. 193 +* Other contactors are open; 194 +* There are no errors from the list below: 195 +** Overcurrent; 196 +** Undervoltage; 197 +** Overvoltage; 198 +** High temperature (charging); 199 +** High temperature (discharging); 200 +** Unallowable charging; 201 +** Critical error. 202 202 203 +In “Always on” mode main contactor opens if all the following is true: 204 + 205 +* Other contactors are open; 206 +* There is an error from the the list above. 207 + 208 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 209 + 210 +In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 211 + 203 203 To change the parameters of the main contactor, select the menu "Cells → Main contactor": 204 204 205 -[[image:173 2209137414-912.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="132" width="352"]]214 +[[image:1739958553206-813.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="410"]] 206 206 207 207 In this section: 208 208 209 209 * Enable – a flag to enable the main contactor control; 219 +* Algorithm – main contactor control algorithm: 220 +** Always on – contactor is always closed; 221 +** Automatic – contactor closes by internal charge and discharge algorithms; 222 +** On demand – contactor is closed by an external request; 210 210 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 211 211 * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset. 212 212
- 1739958553206-813.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.6 KB - Content