... ... @@ -63,7 +63,7 @@ 63 63 * Switch off the charging relay on errors without delay – a flag to protectively open the charging relay without delay. In the opposite case, when an error is detected, the charging relay opens always with the delay “Delay before stopping charging”; 64 64 * Control the precharging relay – a flag that allows control of the precharging relay; 65 65 * Voltage to clear the “Ready to charge” (hence, the “Allow charging”) signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” signal is cleared; 66 -* Voltage to reset the “Ready to charge” (hence, the “Allow charging”) signal – a tolerant U,,ocv,, (corrected voltagedue to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” signal is set;66 +* Voltage to reset the “Ready to charge” (hence, the “Allow charging”) signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” signal is set; 67 67 * Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. 68 68 69 69 (% class="box infomessage" %) ... ... @@ -133,8 +133,8 @@ 133 133 * Switch off the discharging relay on errors without delay – a flag to protectively open the discharging relay without delay. In the opposite case, when an error is detected, the discharging relay opens always with the delay “Delay before stopping discharging”. 134 134 * Precharge time – a duration of closing the precharge relay before closing the discharging relay, millisecond; 135 135 * Precharge current threshold to start discharging – a minimum current value to finish precharging and start discharge, A; 136 -* Voltage to clear the “Ready to discharge” signal – a threshold U,,ocv,, (corrected voltagedue to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;137 -* Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected voltagedue to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set.136 +* Voltage to clear the “Ready to discharge” signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 137 +* Voltage to reset the “Ready to discharge” signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set. 138 138 139 139 === Discharging (AUX) control === 140 140 ... ... @@ -182,31 +182,44 @@ 182 182 183 183 The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor. 184 184 185 -The main contactorclosesifthereare noerrorsfromthe list below:185 +The Main contactor algorithm supports the following modes: 186 186 187 -* Overcurrent; 188 -* Undervoltage; 189 -* Overvoltage; 190 -* High temperature (charging); 191 -* High temperature (discharging); 192 -* Unallowable charging; 193 -* Critical error. 187 +* Always on; 188 +* Automatic; 189 +* On demand. 194 194 195 - The main contactor opens ifthe charging and discharging relaysare opened and any ofthe followingconditionsis met:191 +In “Always on” mode main contactor closes if all the following is true: 196 196 197 -* charging or discharging current is detected during a set time; 198 -* voltage of any cell is lower than the minimum cell voltage configured in the section "Protections → Undervoltage protection" during a set time; 199 -* voltage of any cell is greater than the maximum cell voltage configured in the section "Protections → Overvoltage protection" during a set time; 200 -* temperature of any cell is greater than the maximum cell temperature configured in the section "Protections → High temperature protection" during a set time; 201 -* Critical error stays on during a set time. 193 +* Other contactors are open; 194 +* There are no errors from the list below: 195 +** Overcurrent; 196 +** Undervoltage; 197 +** Overvoltage; 198 +** High temperature (charging); 199 +** High temperature (discharging); 200 +** Unallowable charging; 201 +** Critical error. 202 202 203 +In “Always on” mode main contactor opens if all the following is true: 204 + 205 +* Other contactors are open; 206 +* There is an error from the the list above. 207 + 208 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 209 + 210 +In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 211 + 203 203 To change the parameters of the main contactor, select the menu "Cells → Main contactor": 204 204 205 -[[image:173 2209137414-912.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="132" width="352"]]214 +[[image:1739958553206-813.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="410"]] 206 206 207 207 In this section: 208 208 209 209 * Enable – a flag to enable the main contactor control; 219 +* Algorithm – main contactor control algorithm: 220 +** Always on – contactor is always closed; 221 +** Automatic – contactor closes by internal charge and discharge algorithms; 222 +** On demand – contactor is closed by an external request; 210 210 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 211 211 * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset. 212 212
- 1739958553206-813.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.6 KB - Content