1 +== 3.5.1 Charge control ==
3 3  
4 -(% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 -== Battery control ==
6 -
7 -=== Charge control ===
8 -
9 9  There are two relays that serve charging the battery: a charging relay and an allow charging relay. With the help of the allow charging relay, the BMS commands the charger to start or stop charging.
10 10  
11 11  The board supports two charge control algorithms:
... ... @@ -46,7 +46,7 @@
46 46  
47 47  To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control":
48 48  
49 -[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="725" width="471"]]
43 +[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" height="725" width="471"]]
50 50  
51 51  In this section:
52 52  
... ... @@ -73,7 +73,7 @@
73 73  2) the "Delay before recharging" time has passed since the opening of the allow charging relay.
74 74  )))
75 75  
76 -=== Discharge control ===
70 +== 3.5.2 Discharge control ==
77 77  
78 78  The board has a discharging relay to connect battery to the load.
79 79  
... ... @@ -116,8 +116,9 @@
116 116  
117 117  To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control":
118 118  
119 -[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="644" width="415"]]
113 +[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" height="644" width="415"]]
120 120  
115 +
121 121  In this section:
122 122  
123 123  * Enable – a flag to activate the discharge control;
... ... @@ -132,11 +132,10 @@
132 132  * Use specific delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
133 133  * Switch off the discharging relay on errors without delay – a flag to protectively open the discharging relay without delay. In the opposite case, when an error is detected, the discharging relay opens always with the delay “Delay before stopping discharging”.
134 134  * Precharge time – a duration of closing the precharge relay before closing the discharging relay, millisecond;
135 -* Precharge current threshold to start discharging – a minimum current value to finish precharging and start discharge, A;
136 136  * Voltage to clear the “Ready to discharge” signal – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
137 137  * Voltage to reset the “Ready to discharge” signal – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set.
138 138  
139 -=== Discharging (AUX) control ===
133 +== 3.5.3 Discharging (AUX) control ==
140 140  
141 141  The BMS Main 2.x board can control the power supply of external equipment using the auxiliary (AUX) discharging relay. An example of external equipment can be an inverter that converts DC to AC to power a service laptop and other devices.
142 142  
... ... @@ -150,35 +150,33 @@
150 150  
151 151  To change the parameters of the powering of external equipment, select the menu "Cells → Discharging (AUX) control":
152 152  
153 -[[image:1732208939544-710.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="397" width="445"]]
147 +[[image:1732208939544-710.png||data-xwiki-image-style-alignment="center" height="397" width="445"]]
154 154  
155 155  In this section:
156 156  
157 157  * Enable – a flag to activate the auxiliary discharge control;
158 -* Switch off the discharging (AUX) relay at when the battery SOC is low:
152 +* Switch off the discharging (AUX) relay at low SOC:
159 159  ** Minimum SOC – a minimum SOC value, when reached, the auxiliary (AUX) discharging relay opens, %;
160 160  ** Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging relay re-closes, %;
161 -* Switch off the discharging (AUX) relay when the cell voltage is low:
162 -** Minimum cell voltage – a minimum cell voltage, when reached, the auxiliary (AUX) discharging relay opens, %;
163 -** Tolerant cell voltage – a permissive cell voltage, upon reaching which the auxiliary (AUX) discharging relay re-closes, %;
164 164  * Switch off the discharging (AUX) relay if the battery voltage is out of the range:
165 -** Minimum battery voltage – minimum battery voltage, when reached, the auxiliary (AUX) discharging relay opens,V;
166 -** Maximum battery voltage – maximum battery voltage, upon reaching which the auxiliary (AUX) discharging relay re-closes, V;
156 +** Minimum voltage – minimum battery voltage, V;
157 +** Maximum voltage – maximum battery voltage, V;
167 167  * Switch off the discharging (AUX) relay on errors – the auxiliary (AUX) discharging relay opens if the following errors occur: Undervoltage, Overcurrent, High temperature (discharging), Short circuit, Critical error.
168 168  
169 -=== Charging/Discharging control ===
160 +== 3.5.4 Charging/Discharging control ==
170 170  
171 171   BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as charging contactor when «Charge request» or «Charger connected» are set, otherwise – as discharging contactor.
172 172  
173 173  To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control":
174 174  
175 -[[image:1732209044117-558.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="259"]]
166 +[[image:1732209044117-558.png||data-xwiki-image-style-alignment="center" height="102" width="259"]]
176 176  
168 +
177 177  In this section:
178 178  
179 179  * Enable – a flag to enable Charging/Discharging contactor controller.
180 180  
181 -=== Main contactor ===
173 +== 3.5.5 Main contactor ==
182 182  
183 183  The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor.
184 184  
... ... @@ -202,8 +202,9 @@
202 202  
203 203  To change the parameters of the main contactor, select the menu "Cells → Main contactor":
204 204  
205 -[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="132" width="352"]]
197 +[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" height="132" width="352"]]
206 206  
199 +
207 207  In this section:
208 208  
209 209  * Enable – a flag to enable the main contactor control;
... ... @@ -210,7 +210,7 @@
210 210  * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second;
211 211  * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset.
212 212  
213 -=== Power down control ===
206 +== 3.5.6 Power down control ==
214 214  
215 215  The BMS Main 2.x can command the BMS Power Control board to shut down the battery system if the battery voltage is low or the battery is idle for a long time. The BMS Main 2.x interacts with the BMS Power Control using the “Power down request” and the “Acknowledgement of power down” discrete signals.
216 216  
... ... @@ -223,8 +223,9 @@
223 223  
224 224  To change the parameters of the power down control, select the menu "Cells → Power down control":
225 225  
226 -[[image:1732211675123-235.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="198" width="402"]]
219 +[[image:1732211675123-235.png||data-xwiki-image-style-alignment="center" height="198" width="402"]]
227 227  
221 +
228 228  In this section:
229 229  
230 230  * Enable – a flag to enable the power down control;