Changes for page 3.5 Battery control
Last modified by Admin on 2025/03/10 12:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -159,11 +159,11 @@ 159 159 ** Minimum SOC – a minimum SOC value, when reached, the auxiliary (AUX) discharging relay opens, %; 160 160 ** Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging relay re-closes, %; 161 161 * Switch off the discharging (AUX) relay when the cell voltage is low: 162 -** Minimum cell voltage – a minimum cellvoltage, when reached, the auxiliary (AUX) discharging relay opens, %;163 -** Tolerant cellvoltage– a permissivecellvoltage, upon reaching which the auxiliary (AUX) discharging relay re-closes, %;162 +** Minimum cell voltage – a minimum SOC value, when reached, the auxiliary (AUX) discharging relay opens, %; 163 +** Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging relay re-closes, %; 164 164 * Switch off the discharging (AUX) relay if the battery voltage is out of the range: 165 -** Minimum batteryvoltage – minimum battery voltage,when reached, the auxiliary (AUX) discharging relay opens,V;166 -** Maximum batteryvoltage – maximum battery voltage,upon reaching which the auxiliary (AUX) discharging relay re-closes,V;165 +** Minimum voltage – minimum battery voltage, V; 166 +** Maximum voltage – maximum battery voltage, V; 167 167 * Switch off the discharging (AUX) relay on errors – the auxiliary (AUX) discharging relay opens if the following errors occur: Undervoltage, Overcurrent, High temperature (discharging), Short circuit, Critical error. 168 168 169 169 === Charging/Discharging control ===