Changes for page 3.5 Battery control
Last modified by Admin on 2025/03/10 12:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main 2\.1.3\. Configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -1,11 +1,5 @@ 1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration = 1 +== 3.5.1 Charge control == 3 3 4 -(% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -== Battery control == 6 - 7 -=== Charge control === 8 - 9 9 There are two relays that serve charging the battery: a charging relay and an allow charging relay. With the help of the allow charging relay, the BMS commands the charger to start or stop charging. 10 10 11 11 The board supports two charge control algorithms: ... ... @@ -46,7 +46,7 @@ 46 46 47 47 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 48 48 49 -[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="725" width="471"]]43 +[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" height="725" width="471"]] 50 50 51 51 In this section: 52 52 ... ... @@ -73,7 +73,7 @@ 73 73 2) the "Delay before recharging" time has passed since the opening of the allow charging relay. 74 74 ))) 75 75 76 -== =Discharge control ===70 +== 3.5.2 Discharge control == 77 77 78 78 The board has a discharging relay to connect battery to the load. 79 79 ... ... @@ -116,8 +116,9 @@ 116 116 117 117 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 118 118 119 -[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="644" width="415"]]113 +[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" height="644" width="415"]] 120 120 115 + 121 121 In this section: 122 122 123 123 * Enable – a flag to activate the discharge control; ... ... @@ -135,7 +135,7 @@ 135 135 * Voltage to clear the “Ready to discharge” signal – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 136 136 * Voltage to reset the “Ready to discharge” signal – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set. 137 137 138 -== =Discharging (AUX) control ===133 +== 3.5.3 Discharging (AUX) control == 139 139 140 140 The BMS Main 2.x board can control the power supply of external equipment using the auxiliary (AUX) discharging relay. An example of external equipment can be an inverter that converts DC to AC to power a service laptop and other devices. 141 141 ... ... @@ -149,7 +149,7 @@ 149 149 150 150 To change the parameters of the powering of external equipment, select the menu "Cells → Discharging (AUX) control": 151 151 152 -[[image:1732208939544-710.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="397" width="445"]]147 +[[image:1732208939544-710.png||data-xwiki-image-style-alignment="center" height="397" width="445"]] 153 153 154 154 In this section: 155 155 ... ... @@ -162,19 +162,20 @@ 162 162 ** Maximum voltage – maximum battery voltage, V; 163 163 * Switch off the discharging (AUX) relay on errors – the auxiliary (AUX) discharging relay opens if the following errors occur: Undervoltage, Overcurrent, High temperature (discharging), Short circuit, Critical error. 164 164 165 -== =Charging/Discharging control ===160 +== 3.5.4 Charging/Discharging control == 166 166 167 167 BMS Main 2.x allows to control charging/discharging contactor that combines algorithms of charging and discharging contactor. It behaves as charging contactor when «Charge request» or «Charger connected» are set, otherwise – as discharging contactor. 168 168 169 169 To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control": 170 170 171 -[[image:1732209044117-558.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="102" width="259"]]166 +[[image:1732209044117-558.png||data-xwiki-image-style-alignment="center" height="102" width="259"]] 172 172 168 + 173 173 In this section: 174 174 175 175 * Enable – a flag to enable Charging/Discharging contactor controller. 176 176 177 -== =Main contactor ===173 +== 3.5.5 Main contactor == 178 178 179 179 The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor. 180 180 ... ... @@ -198,8 +198,9 @@ 198 198 199 199 To change the parameters of the main contactor, select the menu "Cells → Main contactor": 200 200 201 -[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="132" width="352"]]197 +[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" height="132" width="352"]] 202 202 199 + 203 203 In this section: 204 204 205 205 * Enable – a flag to enable the main contactor control; ... ... @@ -206,7 +206,7 @@ 206 206 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 207 207 * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset. 208 208 209 -== =Power down control ===206 +== 3.5.6 Power down control == 210 210 211 211 The BMS Main 2.x can command the BMS Power Control board to shut down the battery system if the battery voltage is low or the battery is idle for a long time. The BMS Main 2.x interacts with the BMS Power Control using the “Power down request” and the “Acknowledgement of power down” discrete signals. 212 212 ... ... @@ -219,8 +219,9 @@ 219 219 220 220 To change the parameters of the power down control, select the menu "Cells → Power down control": 221 221 222 -[[image:1732211675123-235.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="198" width="402"]]219 +[[image:1732211675123-235.png||data-xwiki-image-style-alignment="center" height="198" width="402"]] 223 223 221 + 224 224 In this section: 225 225 226 226 * Enable – a flag to enable the power down control;