... ... @@ -65,7 +65,7 @@
65 65  * Voltage to clear the “Ready to charge” (hence, the “Allow charging”) signal – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” signal is cleared;
66 66  * Voltage to reset the “Ready to charge” (hence, the “Allow charging”) signal – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” signal is set;
67 67  * Delay before recharging – a time after which the previously opened the allow charging relay closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;
68 -* Treat positive currents as zero currents for generating the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal at discharging current;
68 +* Treat positive currents as zero currents for generating the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal at charging current.
69 69  
70 70  (% class="box infomessage" %)
71 71  (((