Changes for page 3.5 Battery control
Last modified by Admin on 2025/06/11 15:20
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -drafts. BMS Main\.1.3\. Configuration.WebHome1 +drafts.bms-main-2-1.configuration.WebHome - Content
-
... ... @@ -40,7 +40,7 @@ 40 40 41 41 To change the parameters of the battery charge control algorithm, select the menu "Cells → Charging control": 42 42 43 -[[image:1732208589628-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="725" width="471"]]43 +[[Charge control settings>>image:1732208589628-419.png||data-xwiki-image-style-alignment="center" height="725" width="471"]] 44 44 45 45 In this section: 46 46 ... ... @@ -110,8 +110,9 @@ 110 110 111 111 To change the parameters of the battery discharge control algorithm, select the menu "Cells → Discharging control": 112 112 113 -[[image:1732208781932-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="644" width="415"]]113 +[[Discharge control settings>>image:1732208781932-849.png||data-xwiki-image-style-alignment="center" height="644" width="415"]] 114 114 115 + 115 115 In this section: 116 116 117 117 * Enable – a flag to activate the discharge control; ... ... @@ -143,7 +143,7 @@ 143 143 144 144 To change the parameters of the powering of external equipment, select the menu "Cells → Discharging (AUX) control": 145 145 146 -[[image:1732208939544-710.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="397" width="445"]]147 +[[Discharging (AUX) control settings>>image:1732208939544-710.png||data-xwiki-image-style-alignment="center" height="397" width="445"]] 147 147 148 148 In this section: 149 149 ... ... @@ -162,13 +162,14 @@ 162 162 163 163 To change the parameters of the charging/discharging algorithm, select the menu "Cells → Charging/Discharging control": 164 164 165 -[[image:1732209044117-558.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="102" width="259"]]166 +[[Charging/Discharging control settings>>image:1732209044117-558.png||data-xwiki-image-style-alignment="center" height="102" width="259"]] 166 166 168 + 167 167 In this section: 168 168 169 169 * Enable – a flag to enable Charging/Discharging contactor controller. 170 170 171 -== 3.5.5 Main contactor == 173 +== 3.5.5 Main contactor == 172 172 173 173 The BMS Main 2.x has a relay to control the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactor. 174 174 ... ... @@ -192,32 +192,11 @@ 192 192 193 193 To change the parameters of the main contactor, select the menu "Cells → Main contactor": 194 194 195 -[[image:1732209137414-912.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="132" width="352"]]197 +[[Main contactor settings>>image:1732209137414-912.png||data-xwiki-image-style-alignment="center" height="132" width="352"]] 196 196 199 + 197 197 In this section: 198 198 199 199 * Enable – a flag to enable the main contactor control; 200 200 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 201 201 * Keep the contactor open until the device is reset – a flag for keeping the main contactor opened until the system be reset. 202 - 203 -== 3.5.6 Power down control == 204 - 205 -The BMS Main 2.x can command the BMS Power Control board to shut down the battery system if the battery voltage is low or the battery is idle for a long time. The BMS Main 2.x interacts with the BMS Power Control using the “Power down request” and the “Acknowledgement of power down” discrete signals. 206 - 207 -Shutting down the battery system is performed according to the following conditions: 208 - 209 -* the battery voltage is below the minimum level; 210 -* the “Charger connected” signal is cleared for 60 seconds. 211 - 212 -The BMS Main 2.x also shuts down the battery if it stays in the “Charging OFF”, “Discharging OFF”, “Relaxed (after charging)” or “Relaxed (after discharging)” for the set time. 213 - 214 -To change the parameters of the power down control, select the menu "Cells → Power down control": 215 - 216 -[[image:1732211675123-235.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="198" width="402"]] 217 - 218 -In this section: 219 - 220 -* Enable – a flag to enable the power down control; 221 -* Minimum voltage – a minimum voltage level of the battery below which the BMS commands to shut down the battery, V; 222 -* Idle time – a time of battery inactivity after which the battery is shut down, second; 223 -* Wait the "Power up/down request" signal is cleared (on startup) – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS.