Wiki source code of 3.4 Battery parameters

Version 2.2 by Admin on 2024/11/21 16:19

Show last authors
1 == 3.4.1 Cell defaults ==
2
3 To change the default cell settings, select the menu "Cells → Cell defaults":
4
5 [[Cell default section>>image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]]
6
7 In this section:
8
9 * Capacity – nominal capacity of cells, Ah;
10 * Resistance – nominal (maximum) internal resistance of the cell, Ohm;
11 * Relax time (after charging) – a relaxation time after charging, second;
12 * Relax time (atfer discharging) – the relaxation time after discharging, second;
13 * Cycles – a number of charge-discharge cycles;
14 * Reset battery cycles – a command to reset charge-discharge cycles;
15 * Reset cell parameters (SOC, capacity, resistance) – a command to reset cells state of charge, capacity, and resistance.
16
17 The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and battery.
18
19 The values of “Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery.
20
21 The “Reset cell parameters” command is used for starting-up and adjustment of battery.
22
23 3.4.2 SOC