Changes for page 3.4 Battery parameters
Last modified by Admin on 2025/04/09 12:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -227,10 +227,22 @@ 227 227 228 228 == 3.4.7 Charge current map == 229 229 230 +The BMS Main 2.x board calculates maximum allowable charge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 230 230 232 +Calculated currents values are sending to chargers or intellectual loads over the CAN bus. 233 + 234 +To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 235 + 236 +[[Charge current map settings>>image:1732208033738-498.png||data-xwiki-image-style-alignment="center" height="655" width="453"]] 237 + 231 231 == 3.4.8 Discharge current map == 232 232 240 +The BMS Main 2.x board calculates maximum allowable discharge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 233 233 242 +Calculated currents values are sending to chargers or intellectual loads over the CAN bus. 243 + 244 +To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 245 + 234 234 == 3.4.9 SOC correction == 235 235 236 236 The BMS Main 2.x board can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see section Calculating the state of charge (SOC)).