Changes for page 3.4 Battery parameters

Last modified by Admin on 2025/04/09 12:04

From version 9.3
edited by Admin
on 2024/11/21 16:55
Change comment: There is no comment for this version
To version 10.2
edited by Admin
on 2024/11/21 16:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -241,12 +241,12 @@
241 241  * Maximum charging current – a maximum allowable value of the charge current (under normal conditions):
242 242  * Limit charging current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and temperature;
243 243  * Limit charging current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on the contactor temperature;
244 -* Limit charging current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage;
245 -* Limit charging current by the maximum cell temperature - a flag to enable correction of maximum allowable charging current Kc depending on maximum cell voltage.
244 +* Limit charging current by the maximum cell voltage – a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage;
245 +* Limit charging current by the maximum cell temperature – a flag to enable correction of maximum allowable charging current Kct depending on maximum cell temperature.
246 246  
247 247  Value of the charge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows:
248 248  
249 -Charging current limit = Maximum charging current × Kcs × Kcc × Kcv
249 +Charging current limit = Maximum charging current × Kcs × Kcc × Kcv × Kct.
250 250  
251 251  == 3.4.8 Discharge current map ==
252 252  
... ... @@ -256,6 +256,8 @@
256 256  
257 257  To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map":
258 258  
259 +[[image:1732208218667-968.png]]
260 +
259 259  == 3.4.9 SOC correction ==
260 260  
261 261  The BMS Main 2.x board can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see section Calculating the state of charge (SOC)).
1732208218667-968.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +41.9 KB
Content