Changes for page 3.4 Battery parameters
Last modified by Admin on 2025/04/09 12:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -drafts.bms-main-2 -1.configuration.WebHome1 +drafts.bms-main-2.configuration.WebHome - Content
-
... ... @@ -2,7 +2,7 @@ 2 2 3 3 To change the default cell settings, select the menu "Cells → Cell defaults": 4 4 5 -[[ Cell default section>>image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]]5 +[[image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]] 6 6 7 7 In this section: 8 8 ... ... @@ -31,7 +31,7 @@ 31 31 32 32 To change the parameters of the algorithm for calculating the battery SOC, select the menu "Cells → SOC estimation": 33 33 34 -[[ SOC estimation section>>image:1732206031847-819.png||data-xwiki-image-style-alignment="center" height="849" width="356"]]34 +[[image:1732206031847-819.png||data-xwiki-image-style-alignment="center" height="849" width="356"]] 35 35 36 36 In this section: 37 37 ... ... @@ -81,7 +81,7 @@ 81 81 82 82 To change parameters of the algorithm for calculating the cell resistance, select the menu "Cells → Cell resistance estimation": 83 83 84 -[[ Cell resistance estimation settings>>image:1732207338609-903.png||data-xwiki-image-style-alignment="center" height="187" width="337"]]84 +[[image:1732207338609-903.png||data-xwiki-image-style-alignment="center" height="187" width="337"]] 85 85 86 86 In this section: 87 87 ... ... @@ -119,7 +119,7 @@ 119 119 120 120 To change the cell balancing parameters, select the menu "Cell → Cell balancing": 121 121 122 -[[ Cell balancing settings>>image:1732207485773-804.png||data-xwiki-image-style-alignment="center" height="264" width="387"]]122 +[[image:1732207485773-804.png||data-xwiki-image-style-alignment="center" height="264" width="387"]] 123 123 124 124 In this section: 125 125 ... ... @@ -151,7 +151,7 @@ 151 151 152 152 To change the series balancing parameters, select the menu "Cell → Series balancing": 153 153 154 -[[ Series balancing settings>>image:1732207584941-447.png||data-xwiki-image-style-alignment="center" height="258" width="438"]]154 +[[image:1732207584941-447.png||data-xwiki-image-style-alignment="center" height="258" width="438"]] 155 155 156 156 In this section: 157 157 ... ... @@ -176,7 +176,7 @@ 176 176 177 177 To configure parameters for determining the discharge characteristic of the battery, select the menu "Cells → Cell analysis": 178 178 179 -[[ Cell analysis section>>image:1732207696322-587.png||data-xwiki-image-style-alignment="center" height="213" width="258"]]179 +[[image:1732207696322-587.png||data-xwiki-image-style-alignment="center" height="213" width="258"]] 180 180 181 181 In this section: 182 182 ... ... @@ -227,10 +227,51 @@ 227 227 228 228 == 3.4.7 Charge current map == 229 229 230 +The BMS Main 2.x board calculates maximum allowable charge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 230 230 232 +Calculated currents values are sending to chargers over the CAN bus. 233 + 234 +To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 235 + 236 +[[image:1732208033738-498.png||data-xwiki-image-style-alignment="center" height="655" width="453"]] 237 + 238 +In this section: 239 + 240 +* Enable – a flag to start calculation of the charge current limit; 241 +* Maximum charging current – a maximum allowable value of the charge current (under normal conditions): 242 +* Limit charging current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and temperature; 243 +* Limit charging current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on the contactor temperature; 244 +* Limit charging current by the maximum cell voltage – a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage; 245 +* Limit charging current by the maximum cell temperature – a flag to enable correction of maximum allowable charging current Kct depending on maximum cell temperature. 246 + 247 +Value of the charge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows: 248 + 249 +Charging current limit = Maximum charging current × Kcs × Kcc × Kcv × Kct. 250 + 231 231 == 3.4.8 Discharge current map == 232 232 253 +The BMS Main 2.x board calculates maximum allowable discharge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 233 233 255 +Calculated currents values are sending or intellectual loads over the CAN bus. 256 + 257 +To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 258 + 259 +[[image:1732208218667-968.png||data-xwiki-image-style-alignment="center" height="631" width="434"]] 260 + 261 +In this section: 262 + 263 +* Enable – a flag to start calculation of the discharge current limit; 264 +* Maximum discharging current – a maximum allowable value of the discharge current (under normal conditions): 265 +* Current factor – the dependence of the correction factor on SOC and the battery temperature – Kdischarge=Kdischarge (SOC, t°C). 266 +* Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature; 267 +* Limit discharging current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on the contactor temperature; 268 +* Limit discharging current by the maximum cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on maximum cell voltage; 269 +* Limit discharging current by the maximum cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on maximum cell temperature . 270 + 271 +Value of the discharge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows: 272 + 273 +Discharging current limit = Maximum discharging current × Kds × Kdc × Kdv × Kdt. 274 + 234 234 == 3.4.9 SOC correction == 235 235 236 236 The BMS Main 2.x board can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see section Calculating the state of charge (SOC)). ... ... @@ -237,7 +237,7 @@ 237 237 238 238 To configure parameters for periodically correcting the battery state of charge, select the menu "Cells → SOC correction": 239 239 240 -[[ SOC correction settings>>image:1732206262509-786.png||data-xwiki-image-style-alignment="center" height="291" width="298"]]281 +[[image:1732206262509-786.png||data-xwiki-image-style-alignment="center" height="291" width="298"]] 241 241 242 242 In this section: 243 243
- 1732208218667-968.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.9 KB - Content