Changes for page 3.4 Battery parameters

Last modified by Admin on 2025/04/09 12:04

From version 4.1
edited by Admin
on 2024/11/21 16:24
Change comment: Uploaded new attachment "1732206262509-786.png", version {1}
To version 4.2
edited by Admin
on 2024/11/21 16:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -61,10 +61,12 @@
61 61  
62 62  The SOC calculation algorithm “Current and voltage (enhanced)” differs from the simplified algorithm by online correction of effective capacitance. When using this algorithm, it is necessary to fine tune the tabular dependence Uocv = Uocv (SOC, t °C).
63 63  
64 -3.4.3 SOC correction
64 +== 3.4.3 SOC correction ==
65 65  
66 66  The BMS Main 2.x board can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see section Calculating the state of charge (SOC)).
67 67  
68 68  To configure parameters for periodically correcting the battery state of charge, select the menu "Cells → SOC correction":
69 69  
70 +[[SOC correction settings>>image:1732206262509-786.png||data-xwiki-image-style-alignment="center" height="291" width="298"]]
71 +
70 70