Changes for page 3.4 Battery parameters

Last modified by Admin on 2026/04/24 10:30

From version 35.9
edited by Admin
on 2026/04/24 10:29
Change comment: Update document after refactoring.
To version 35.11
edited by Admin
on 2026/04/24 10:30
Change comment: Renamed back-links.

Summary

Details

Page properties
Content
... ... @@ -136,7 +136,7 @@
136 136  * the voltage on the cell is less than the balancing stop voltage;
137 137  * the difference between the voltage on the cell and the minimum voltage among the battery cells is less than the balancing stop threshold.
138 138  
139 -If the BMS Logic board overheats, then the balancing of the cells connected to this board will not be performed (see [[Logic high temperature protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLogichightemperatureprotection"]]).
139 +If the BMS Logic board overheats, then the balancing of the cells connected to this board will not be performed (see [[Logic high temperature protection>>doc:Battery management systems.BMS Main 2\.1 (End-of-Life).3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLogichightemperatureprotection"]]).
140 140  
141 141  The BMS Main 2.1 can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold.
142 142  
... ... @@ -170,7 +170,7 @@
170 170  
171 171  The BMS Main 2.x board supports work with two independent (galvanically unrelated) cell series. To monitor the status of two series, two current sensors are used: primary and secondary (AUX). A series of cells must be equivalent: they must have the same number of cells and the same capacity.
172 172  
173 -Since the series of cells can operate at different loads, they must be balanced. For this, the BMS Main 2.x provides two relays: “Balancing series 1” and “Balancing series 2” (see [[Input and output signals>>doc:Battery management systems.BMS Main 2\.1 (End-of-Life).3\. Configuration.3\.3 Input and output signals.WebHome]]), as well as a combined algorithm that considers both the voltage of each series and the charge that these series gave load. “Balancing series 1” and “Balancing series 2” relays are used to connect high-power balancing resistors in parallel with cells series 1 and 2.
173 +Since the series of cells can operate at different loads, they must be balanced. For this, the BMS Main 2.x provides two relays: “Balancing series 1” and “Balancing series 2” (see [[Input and output signals>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.3 Input and output signals.WebHome]]), as well as a combined algorithm that considers both the voltage of each series and the charge that these series gave load. “Balancing series 1” and “Balancing series 2” relays are used to connect high-power balancing resistors in parallel with cells series 1 and 2.
174 174  
175 175  When charging the battery, balancing is performed based on the voltage of the series. A balancing resistor is connected to the cell series if:
176 176