74 74  Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value
75 75  
76 -{{formula fontSize="SMALL" imageType="PNG"}}
77 -R = \frac{U-U_{ocv}}{I_{stable}}
78 -{{/formula}}
76 +R = (U-Uocv) / Istable,
79 79  
80 80  where U is the cell voltage measured in the charge or discharge state, V; Uocv is the cell voltage measured in the state of relaxation (before switching to the state of charge or discharge); Istable – stabilized current through the cell in the state of charge or discharge.
81 81  
82 82  The second method is used for a stepwise change in the current through the cell, while the value of the cell resistance:
83 83  
84 -{{formula fontSize="SMALL"}}
85 -R = \frac{U_2-U_1}{I_{stable2}-I_{stable1}}
86 -{{/formula}}
82 +R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,,
87 87  
88 -provided that
84 +(Q,,max,, is the maximum cell capacity),
89 89  
90 -{{formula fontSize="SMALL"}}
91 -| I_{stable2}-I_{stable1} | > 0.2 × Q_{max}
92 -{{/formula}}
86 +where U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it.
93 93  
94 -where Q,,max,, is the maximum cell capacity; U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it.
95 -
96 96  The stabilized current I,,stable,, = I, if during the stabilization time the instantaneous current I is in the range from 0.95 × I to 1.05 × I.
97 97  
98 98  To change parameters of the algorithm for calculating the cell resistance, select the menu "Cells → Cell resistance estimation":
... ... @@ -257,7 +257,7 @@
257 257  
258 258  === Charge current map ===
259 259  
260 -The BMS Main 2.x board calculates maximum allowable charge current values in respect to cell SOC and battery temperature, contactor temperature and maximum cell voltage.
252 +The BMS Main 2.x board calculates maximum allowable charge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage.
261 261  
262 262  Calculated currents values are sending to chargers over the CAN bus.
263 263  
... ... @@ -269,9 +269,9 @@
269 269  
270 270  * Enable – a flag to start calculation of the charge current limit;
271 271  * Maximum charging current – a maximum allowable value of the charge current (under normal conditions):
272 -* Limit charging current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on the __maximum cell SOC__ and temperature;
264 +* Limit charging current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and temperature;
273 273  * Limit charging current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on the contactor temperature;
274 -* Limit charging current by the maximum cell voltage – a flag to enable correction of maximum allowable charging current Kcv depending on __the maximum cell voltage__;
266 +* Limit charging current by the maximum cell voltage – a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage;
275 275  * Limit charging current by the maximum cell temperature – a flag to enable correction of maximum allowable charging current Kct depending on cell temperature.
276 276  
277 277  Value of the charge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows:
... ... @@ -280,7 +280,7 @@
280 280  
281 281  === Discharge current map ===
282 282  
283 -The BMS Main 2.x board calculates maximum allowable discharge current values in respect to cell SOC and battery temperature, contactor temperature and minimum cell voltage.
275 +The BMS Main 2.x board calculates maximum allowable discharge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage.
284 284  
285 285  Calculated currents values are sending or intellectual loads over the CAN bus.
286 286