Changes for page 3.4 Battery parameters
Last modified by Admin on 2025/04/09 12:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -73,24 +73,26 @@ 73 73 74 74 Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value 75 75 76 -R = (U-Uocv) / Istable, 76 +{{formula fontSize="SMALL" imageType="PNG"}} 77 +R = \frac{U-U_{ocv}}{I_{stable}} 78 +{{/formula}} 77 77 78 78 where U is the cell voltage measured in the charge or discharge state, V; Uocv is the cell voltage measured in the state of relaxation (before switching to the state of charge or discharge); Istable – stabilized current through the cell in the state of charge or discharge. 79 79 80 80 The second method is used for a stepwise change in the current through the cell, while the value of the cell resistance: 81 81 82 -R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) 84 +{{formula fontSize="SMALL"}} 85 +R = \frac{U_2-U_1}{I_{stable2}-I_{stable1}} 86 +{{/formula}} 83 83 84 84 provided that 85 85 86 - ~{~{formula fontSize="SMALL"}}87 - ~| I_{stable2}-I_{stable1} | > 0.2 × Qmax88 - ~{~{/formula}}90 +{{formula fontSize="SMALL"}} 91 +| I_{stable2}-I_{stable1} | > 0.2 × Q_{max} 92 +{{/formula}} 89 89 90 - (Q,,max,, is the maximum cell capacity),94 +where Q,,max,, is the maximum cell capacity; U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it. 91 91 92 -where U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it. 93 - 94 94 The stabilized current I,,stable,, = I, if during the stabilization time the instantaneous current I is in the range from 0.95 × I to 1.05 × I. 95 95 96 96 To change parameters of the algorithm for calculating the cell resistance, select the menu "Cells → Cell resistance estimation": ... ... @@ -255,7 +255,7 @@ 255 255 256 256 === Charge current map === 257 257 258 -The BMS Main 2.x board calculates maximum allowable charge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 260 +The BMS Main 2.x board calculates maximum allowable charge current values in respect to cell SOC and battery temperature, contactor temperature and maximum cell voltage. 259 259 260 260 Calculated currents values are sending to chargers over the CAN bus. 261 261 ... ... @@ -267,9 +267,9 @@ 267 267 268 268 * Enable – a flag to start calculation of the charge current limit; 269 269 * Maximum charging current – a maximum allowable value of the charge current (under normal conditions): 270 -* Limit charging current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and temperature; 272 +* Limit charging current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on the __maximum cell SOC__ and temperature; 271 271 * Limit charging current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on the contactor temperature; 272 -* Limit charging current by the maximum cell voltage – a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage; 274 +* Limit charging current by the maximum cell voltage – a flag to enable correction of maximum allowable charging current Kcv depending on __the maximum cell voltage__; 273 273 * Limit charging current by the maximum cell temperature – a flag to enable correction of maximum allowable charging current Kct depending on cell temperature. 274 274 275 275 Value of the charge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows: ... ... @@ -278,11 +278,11 @@ 278 278 279 279 === Discharge current map === 280 280 281 -The BMS Main 2.x board calculates maximum allowable discharge current values in respect to SOC and battery temperature, contactor temperature and m aximum cell voltage.283 +The BMS Main 2.x board calculates maximum allowable discharge current values in respect to cell SOC and battery temperature, contactor temperature and minimum cell voltage. 282 282 283 283 Calculated currents values are sending or intellectual loads over the CAN bus. 284 284 285 -To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 287 +To configure parameters for determining the discharge current limit, select the menu "Cells → Charge current map": 286 286 287 287 [[image:1732208218667-968.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="631" width="434"]] 288 288 ... ... @@ -291,9 +291,9 @@ 291 291 * Enable – a flag to start calculation of the discharge current limit; 292 292 * Maximum discharging current – a maximum allowable value of the discharge current (under normal conditions): 293 293 * Current factor – the dependence of the correction factor on SOC and the battery temperature – Kdischarge=Kdischarge (SOC, t°C). 294 -* Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature; 296 +* Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending __on the minimum cell SOC__ and temperature; 295 295 * Limit discharging current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on the contactor temperature; 296 -* Limit discharging current by the maximum cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on m aximum cell voltage;298 +* Limit discharging current by the maximum cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending __on the minimum cell voltage__; 297 297 * Limit discharging current by the maximum cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on cell temperature . 298 298 299 299 Value of the discharge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows: