48 48  * Final SOC – a method of calculating the battery SOC:
49 49  ** Minimum cell SOC – the battery SOC is assumed to be equal to the minimum SOC of cells;
50 50  ** Average cell SOC – the battery SOC is assumed to be equal to the average SOC of cells;
51 -** Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if any cell has 100% SOC, b) 0% if any cell has 0% SOC;
52 -** Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC;
53 53  * Scale the final SOC – flag to scale the battery SOC by the following values;
54 54  * Internal SOC corresponding to 0% – battery SOC that sets to be 0%;
55 55  * Internal SOC corresponding to 100% – battery SOC that sets to be 100%.
... ... @@ -79,14 +79,8 @@
79 79  
80 80  The second method is used for a stepwise change in the current through the cell, while the value of the cell resistance:
81 81  
82 -R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,)
80 +R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,,
83 83  
84 -provided that
85 -
86 -~{~{formula fontSize="SMALL"}}
87 -~| I_{stable2}-I_{stable1} | > 0.2 × Qmax
88 -~{~{/formula}}
89 -
90 90  (Q,,max,, is the maximum cell capacity),