... ... @@ -79,10 +79,8 @@
79 79  
80 80  The second method is used for a stepwise change in the current through the cell, while the value of the cell resistance:
81 81  
82 -R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,)
82 +R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,,
83 83  
84 -provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,,
85 -
86 86  (Q,,max,, is the maximum cell capacity),
87 87  
88 88  where U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it.