Changes for page 3.4 Battery parameters
Last modified by Admin on 2025/04/09 12:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -48,8 +48,6 @@ 48 48 * Final SOC – a method of calculating the battery SOC: 49 49 ** Minimum cell SOC – the battery SOC is assumed to be equal to the minimum SOC of cells; 50 50 ** Average cell SOC – the battery SOC is assumed to be equal to the average SOC of cells; 51 -** Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if any cell has 100% SOC, b) 0% if any cell has 0% SOC; 52 -** Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC; 53 53 * Scale the final SOC – flag to scale the battery SOC by the following values; 54 54 * Internal SOC corresponding to 0% – battery SOC that sets to be 0%; 55 55 * Internal SOC corresponding to 100% – battery SOC that sets to be 100%. ... ... @@ -79,10 +79,8 @@ 79 79 80 80 The second method is used for a stepwise change in the current through the cell, while the value of the cell resistance: 81 81 82 -R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) 80 +R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,, 83 83 84 -provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,, 85 - 86 86 (Q,,max,, is the maximum cell capacity), 87 87 88 88 where U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it. ... ... @@ -138,7 +138,7 @@ 138 138 139 139 To change the cell balancing parameters, select the menu "Cell → Cell balancing": 140 140 141 -[[image:173 9812799920-892.png||alt="1732207485773-804.png"data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="264" width="387"]]137 +[[image:1732207485773-804.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="264" width="387"]] 142 142 143 143 In this section: 144 144 ... ... @@ -150,13 +150,8 @@ 150 150 ** Charging; 151 151 ** Charging or relaxed; 152 152 ** Always (regardless of battery state); 153 -* Balancing condition: 154 -** Automatic – balancing will be performed automatically if needed conditions are met; 155 -** On balancing request – balancing will start only if a remote request is received. In this case cells will start to balance regardless the "Voltage deviation to start balancing" value; 156 156 * Minimum cell voltage to start balancing, V; 157 -* Deviation to start balancing; 158 -* Deviation to stop balancing; 159 -* Voltage for forced balancing – if cell voltage is above this value, it will start discharging through balancing resistor; 150 +* Balancing threshold, V; 160 160 * Start cell discharging – a command to start forced balancing of all battery cells (used for service purposes); 161 161 * Stop cell discharging – a command to stop forced balancing of all battery cells (used for service purposes). 162 162