Changes for page 3.4 Battery parameters
Last modified by Admin on 2025/04/09 12:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main 2\.1.3\. Configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -1,11 +1,5 @@ 1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration = 1 +== 3.4.1 Cell defaults == 3 3 4 -(% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -== Battery parameters == 6 - 7 -=== Cell defaults === 8 - 9 9 To change the default cell settings, select the menu "Cells → Cell defaults": 10 10 11 11 [[image:1732205873121-893.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="281" width="374"]] ... ... @@ -26,7 +26,7 @@ 26 26 27 27 The “Reset cell parameters” command is used for starting-up and adjustment of battery. 28 28 29 -== =SOC estimation ===23 +== 3.4.2 SOC estimation == 30 30 31 31 The BMS Main 2.x board calculates the state of charge of the battery (SOC) using two algorithms: 32 32 ... ... @@ -51,7 +51,7 @@ 51 51 * Scale the final SOC – flag to scale the battery SOC by the following values; 52 52 * Internal SOC corresponding to 0% – battery SOC that sets to be 0%; 53 53 * Internal SOC corresponding to 100% – battery SOC that sets to be 100%. 54 -* Uocv = Uocv(SOC, t °C) – the dependence of the cell open circuit voltage Uocv on SOC and the cell temperature (selected for specific batteries, can be established experimentally – see [[Cell analysis>>doc:||anchor="HCellanalysis"]]); 48 +* Uocv = Uocv(SOC, t °C) – the dependence of the cell open circuit voltage Uocv on SOC and the cell temperature (selected for specific batteries, can be established experimentally – see [[3.4.6 Cell analysis>>doc:||anchor="H3.4.6Cellanalysis"]]); 55 55 * Linear zone – linear zone of dependence Uocv = Uocv(SOC, t °C): 56 56 ** Uocv ,,[point 1],, – starting point of the linear zone; 57 57 ** Uocv ,,[point 2],, – end point of the linear zone; ... ... @@ -67,7 +67,7 @@ 67 67 68 68 The SOC calculation algorithm “Current and voltage (enhanced)” differs from the simplified algorithm by online correction of effective capacitance. When using this algorithm, it is necessary to fine tune the tabular dependence Uocv = Uocv (SOC, t °C). 69 69 70 -== =Cell resistance estimation ===64 +== 3.4.3 Cell resistance estimation == 71 71 72 72 Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value 73 73 ... ... @@ -97,9 +97,9 @@ 97 97 * Minimum SOC – minimum cell SOC value for resistance calculation; 98 98 * Maximum SOC – maximum cell SOC value for resistance calculation. 99 99 100 -The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Cell defaults>>doc:||anchor=" HCelldefaults"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).94 +The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[3.4.1 Cell defaults>>doc:||anchor="3.4.1 Cell defaults"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance). 101 101 102 -== =Cell balancing ===96 +== 3.4.4 Cell balancing == 103 103 104 104 The BMS Main 2.x supports two cell balancing algorithms: 105 105 ... ... @@ -121,17 +121,8 @@ 121 121 * the voltage on the cell is higher than the starting voltage of the balancing; 122 122 * the difference between the cell voltage and the minimum voltage among the cells of the battery is greater than the balancing threshold. 123 123 124 - Abalancingresistorisdisconnectedfromthecellif anyofthe following conditionsare met:118 +If the BMS Logic board overheats, then the balancing of the cells connected to this board will not be performed (see [[3.6.18 Logic high temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.18 Logic high temperature protection"]]). 125 125 126 -* the voltage on the cell is less than the balancing stop voltage; 127 -* the difference between the voltage on the cell and the minimum voltage among the battery cells is less than the balancing stop threshold. 128 - 129 -If the BMS Logic board overheats, then the balancing of the cells connected to this board will not be performed (see [[Logic high temperature protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLogichightemperatureprotection"]]). 130 - 131 -The BMS Main 2.1 can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 132 - 133 -BMS Main 2.1 can force a cell balancing, if its voltage is higher than estimated value. 134 - 135 135 To change the cell balancing parameters, select the menu "Cell → Cell balancing": 136 136 137 137 [[image:1732207485773-804.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="264" width="387"]] ... ... @@ -151,11 +151,11 @@ 151 151 * Start cell discharging – a command to start forced balancing of all battery cells (used for service purposes); 152 152 * Stop cell discharging – a command to stop forced balancing of all battery cells (used for service purposes). 153 153 154 -== =Series balancing ===139 +== 3.4.5 Series balancing == 155 155 156 156 The BMS Main 2.x board supports work with two independent (galvanically unrelated) cell series. To monitor the status of two series, two current sensors are used: primary and secondary (AUX). A series of cells must be equivalent: they must have the same number of cells and the same capacity. 157 157 158 -Since the series of cells can operate at different loads, they must be balanced. For this, the BMS Main 2.x provides two relays: “Balancing series 1” and “Balancing series 2” (see [[Input and output signals>>doc: Battery managementystems.BMS Main 2\.1.3\. Configuration.3\.3 Input and output signals.WebHome]]), as well as a combined algorithm that considers both the voltage of each series and the charge that these series gave load. “Balancing series 1” and “Balancing series 2” relays are used to connect high-power balancing resistors in parallel with cells series 1 and 2.143 +Since the series of cells can operate at different loads, they must be balanced. For this, the BMS Main 2.x provides two relays: “Balancing series 1” and “Balancing series 2” (see [[3.3 Input and output signals>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.3 Input and output signals.WebHome]]), as well as a combined algorithm that considers both the voltage of each series and the charge that these series gave load. “Balancing series 1” and “Balancing series 2” relays are used to connect high-power balancing resistors in parallel with cells series 1 and 2. 159 159 160 160 When charging the battery, balancing is performed based on the voltage of the series. A balancing resistor is connected to the cell series if: 161 161 ... ... @@ -177,9 +177,9 @@ 177 177 * Coulomb threshold – the difference of the charges Qthr, given by a series of cells, above which balancing to be started, Ah; 178 178 * Period – period to reset of charge counters for each series (to avoid accumulation of error), second. 179 179 180 -== =Cell analysis ===165 +== 3.4.6 Cell analysis == 181 181 182 -Discharge characteristics of the battery – the dependence Uocv = Uocv (DOD) – is used to determine the tabular dependence Uocv = Uocv (SOC, t °C) (see [[SOC estimation>>doc:||anchor=" HSOCestimation"]]), which is necessary for calculating the state of charge of the battery.167 +Discharge characteristics of the battery – the dependence Uocv = Uocv (DOD) – is used to determine the tabular dependence Uocv = Uocv (SOC, t °C) (see [[3.4.2 SOC estimation>>doc:||anchor="3.4.2 SOC estimation"]]), which is necessary for calculating the state of charge of the battery. 183 183 184 184 The BMS Main 2.x board can automatically determine the battery discharge characteristic. 185 185 ... ... @@ -240,7 +240,7 @@ 240 240 * OCV – cell voltage Uocv, V; 241 241 * Resistance – cell resistance, Ohm. 242 242 243 -== =Charge current map ===228 +== 3.4.7 Charge current map == 244 244 245 245 The BMS Main 2.x board calculates maximum allowable charge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 246 246 ... ... @@ -263,7 +263,7 @@ 263 263 264 264 Charging current limit = Maximum charging current × Kcs × Kcc × Kcv × Kct. 265 265 266 -== =Discharge current map ===251 +== 3.4.8 Discharge current map == 267 267 268 268 The BMS Main 2.x board calculates maximum allowable discharge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 269 269 ... ... @@ -287,9 +287,9 @@ 287 287 288 288 Discharging current limit = Maximum discharging current × Kds × Kdc × Kdv × Kdt. 289 289 290 -== =SOC correction ===275 +== 3.4.9 SOC correction == 291 291 292 -The BMS Main 2.x board can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see [[SOC estimation>>doc:||anchor=" HSOCestimation"]]).277 +The BMS Main 2.x board can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see [[3.4.2 SOC estimation>>doc:||anchor="3.4.2 SOC estimation"]]). 293 293 294 294 To configure parameters for periodically correcting the battery state of charge, select the menu "Cells → SOC correction": 295 295
- 1739812799920-892.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.1 KB - Content