Changes for page 3.4 Battery parameters

Last modified by Admin on 2025/04/09 12:04

From version 23.1
edited by Admin
on 2024/12/02 15:24
Change comment: There is no comment for this version
To version 24.1
edited by Admin
on 2024/12/02 15:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -91,7 +91,7 @@
91 91  * Minimum SOC – minimum cell SOC value for resistance calculation;
92 92  * Maximum SOC – maximum cell SOC value for resistance calculation.
93 93  
94 -The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[3.4.1 Cell defaults>>doc:||anchor="3.4.1 Cell defaults"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
94 +The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[3.4.1 Cell defaults>>doc:||anchor="H3.4.1Celldefaults"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
95 95  
96 96  == 3.4.4 Cell balancing ==
97 97  
... ... @@ -115,7 +115,7 @@
115 115  * the voltage on the cell is higher than the starting voltage of the balancing;
116 116  * the difference between the cell voltage and the minimum voltage among the cells of the battery is greater than the balancing threshold.
117 117  
118 -If the BMS Logic board overheats, then the balancing of the cells connected to this board will not be performed (see [[3.6.18 Logic high temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.18 Logic high temperature protection"]]).
118 +If the BMS Logic board overheats, then the balancing of the cells connected to this board will not be performed (see [[3.6.18 Logic high temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.18Logichightemperatureprotection"]]).
119 119  
120 120  To change the cell balancing parameters, select the menu "Cell → Cell balancing":
121 121  
... ... @@ -164,7 +164,7 @@
164 164  
165 165  == 3.4.6 Cell analysis ==
166 166  
167 -Discharge characteristics of the battery – the dependence Uocv = Uocv (DOD) – is used to determine the tabular dependence Uocv = Uocv (SOC, t °C) (see [[3.4.2 SOC estimation>>doc:||anchor="3.4.2 SOC estimation"]]), which is necessary for calculating the state of charge of the battery.
167 +Discharge characteristics of the battery – the dependence Uocv = Uocv (DOD) – is used to determine the tabular dependence Uocv = Uocv (SOC, t °C) (see [[3.4.2 SOC estimation>>doc:||anchor="H3.4.2SOCestimation"]]), which is necessary for calculating the state of charge of the battery.
168 168  
169 169  The BMS Main 2.x board can automatically determine the battery discharge characteristic.
170 170  
... ... @@ -274,7 +274,7 @@
274 274  
275 275  == 3.4.9 SOC correction ==
276 276  
277 -The BMS Main 2.x board can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see [[3.4.2 SOC estimation>>doc:||anchor="3.4.2 SOC estimation"]]).
277 +The BMS Main 2.x board can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see [[3.4.2 SOC estimation>>doc:||anchor="H3.4.2SOCestimation"]]).
278 278  
279 279  To configure parameters for periodically correcting the battery state of charge, select the menu "Cells → SOC correction":
280 280