Changes for page 3.4 Battery parameters
Last modified by Admin on 2025/04/09 12:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -285,6 +285,7 @@ 285 285 * Enable – a flag to enable SOC correction; 286 286 * Shutdown period – a time the battery is off, day. If the BMS detects on its startup that it was off during the “Shutdown period” time, the BMS recalculates the battery state of charge base on the tabular dependency Uocv = Uocv (SOC, t); 287 287 * Correction period – a period of correcting the battery SOC, day. If the BMS detects that the last correction was more than the “Correction period” ago, the BMS recalculates the battery state of charge base on the tabular dependency Uocv = Uocv (SOC, t) and tunes it gradually during the “SOC change time”; 288 -* SOC change time – a duration of the linear changing the battery SOC to the value calculated by the correction algorithm, minute. 288 +* SOC change time – a duration of the linear changing the battery SOC to the value calculated by the correction algorithm, minute; 289 +* Ignore the linear zone – a flag to ignore linear zone while calculating SOC correction. 289 289 290 290